期刊文献+

变频器驱动电机时的EMI影响分析

Influence Analysis of EMI in Power Converter Drive System
下载PDF
导出
摘要 PWM逆变器驱动电机因其具有优越的控制性能而得到了广泛的应用,然而由于逆变器的开关模式带来的电磁干扰问题,也给电机带来了不少负面影响。在给出了电机和电缆高频模型的基础上,分别对不同电缆长度和不同开关频率对电机过电压的影响进行了仿真分析。最后搭建了实验平台,用频谱分析仪对电机的EMI进行测试,验证了上述不同因素对电机EMI影响的分析。 Due to the improvement of control performance,PWM inverters are widely used in motor drive system.However,the electromagnetic interference (EMI) has undesirable effects on motor which produced by the inverters because of the operation of switch mode.The high frequency model of the power cable and motor was designed.The influence of system parameters such as cable lengths and the switching frequencies of the inverter on motor terminal overvoltage was analyzed.The experimental platform was setted up and the EMI in motor was tested by the spectrum analyzer.The test results show good agreement with the simulate analysis result.
出处 《电气传动》 北大核心 2013年第10期61-64,共4页 Electric Drive
关键词 PWM逆变器 电机高频模型 电缆长度 电磁传导干扰 PWM inverter the high frequency model of motor power cable length electromagnetic interference (EMI)
  • 相关文献

参考文献7

  • 1孟进,马伟明,张磊,潘启军,赵治华.PWM变频驱动系统传导干扰的高频模型[J].中国电机工程学报,2008,28(15):141-146. 被引量:57
  • 2Li Ran, Sunil Gokani, Jon Clare.Conducted Electromagnetic Emission in Induction Motor Drive Systems Partl : Time Do- main in Analysis and Identification of Dominant Modes [ J ]. IEEE Transactions on Power Electronics, 1998, 13 (4) : 757-767.
  • 3陈斌,姜建国,孙旭东.PWM逆变器-感应电机驱动系统中接地电流EMI问题的分析[J].中国电机工程学报,2003,23(2):58-62. 被引量:47
  • 4Li Ran, Sunil Gokani, Jon Clare.Conducted Electromagnetic Emission in Induction Motor Drive Systems Part2: Frequency- Domain Models [J].IEEE Transactions on Power Electronics, 1998,13(4) :768-776.
  • 5王兆安 黄俊.电力电子技术[M].北京:机械工业出版社,2004..
  • 6葛兴来,冯晓云,刘柏思.PWM整流器谐波特性分析[J].电力电子技术,2009,43(4):67-69. 被引量:18
  • 7Dezza F C, Monti A, Scaglia A. High Power AC/DC Converter and DC/AC Inverter for High Speed Train Application [C]// Proceedings of TENCON, 2000( 1 ) : 24-27.

二级参考文献24

  • 1裴雪军,康勇,熊健,陈坚.PWM逆变器共模传导电磁干扰的预测[J].中国电机工程学报,2004,24(8):83-88. 被引量:69
  • 2Dezza F C,Monti A,Scaglia A.High Power AC/DC Converter and DC/AC Inverter for High Speed Train Application [A].Proceedings of TENCON[C].2000, ( 1 ) : 24-27.
  • 3Xu Jiang,Xiangning Xiao,Hao Liu,et al.The Output Spectrum Analysis of High-power Multilevel Voltage Source Converters using Double Fourier Series [A].Transmission and Distribution Conference and Exhibition[C].Asia and Pacific, 2005 : 1-5.
  • 4Wu C M,Lau W H,Chang H.Analytical Solution to Harmonic Characteristics of PWM H-bridge Converters with Dead Time[A].Proceedings of IEEE ISCAS[C].1998, (6): 462-465.
  • 5Chang G W,Hsin Wei Lin,Shin Kuan Chen.Modeling Characteristics of Harmonic Currents generated by High-Speed Railway Traction Drive Converters[J].IEEE Trans. on Power Delivery, 2004, (19) : 766-773.
  • 6Skibinski G, Kerkman R, Schlegel D. EMI emissions of modem PWM ac drives[J]. IEEE Industry Applications Magazine, 1999, 5(6): 47-81.
  • 7Grandi G, Cadadei D, Reggiani U. Common-and Differentuial-model HF current components in AC motors supplied by voltage source inverters[J]. IEEE Trans. on Power Electronics, 2004, 19(1): 16-24.
  • 8Ran L, Clare J, Bradley K, et al. Conducted electromagnetic emissions in induction motor drive systems part 1: time domain analysis and identification of dominant modes[J]. IEEE Trans. on Power Electronics, 1998, 13(4): 757-767.
  • 9Ran L, Clare J, Bradley K, et al. Conducted electromagnetic emissions in induction motor drive systems part 2: frequency domain models [J]. IEEETrans. on PowerElectronics, 1998, 13(4): 768-776.
  • 10Zhu H, Lai J, Hefner A, et al. Modeling-based examination of conducted EMI emission for hard-and soft-switching PWM inverters [J]. IEEE Trans. on Industry Applications, 2001, 37(5): 1383-1393.

共引文献190