摘要
通信技术的快速发展导致通信电源的需求呈现爆发性增长,大量蓄电池成为通信电源的核心环节,其测试和维护是一项重要而繁重的工作。文章主要介绍了目前蓄电池维护的一些技术,并引入一种铅酸蓄电池自动脉冲维护技术,通过实践证明该项技术能够防止蓄电池极板发生硫酸盐结晶,减缓蓄电池年度5%~10%的衰老现象,延长蓄电池的使用年限,并适用于各种类型的电池和工作环境。
The rapid development of communication technology led to the demand for communication power growing rapidly. As the key link of telecom power, the testing and maintenance of the battery are an important and heavy work. The battery maintenance technology and the introduction of a lead-acid battery automatic pulse maintenance technology are described in this paper. The results showed that this technology is able to prevent the battery plate sulfate crystallization and prevent the aging of the battery 5% to 1()~ for each year, and lengthen the service life of the battery, and it is applied to all kinds of batteries and workin~ environments.
出处
《通信电源技术》
2013年第5期55-57,60,共4页
Telecom Power Technology
关键词
蓄电池
容量
微电流均充
脉冲放电
battery capacity micro-current equalize charge pulse discharge