摘要
针对石油化工控制室抗爆设计采用的等效单自由体系动力分析涉及到的质量和荷载传递系数的确定方法进行讨论,并对《石油化工控制室抗爆设计规范》GB 50779-2012附录B中质量和荷载传递系数进行补充和完善。
This paper discusses the transfer coefficient determination method of component mass and load of the dynamic analysis of equivalent single freedom system used in the antiknock design of petrochemical control room,and the mass and load transfer coefficient in Appendix B of GB50779-2012 ' Petrochemical Control Room Antiknock Design Specification'is supplemented and perfected in this paper.
出处
《化工设计》
CAS
2013年第5期39-41,2,共3页
Chemical Engineering Design
关键词
石油化工控制室抗爆设计
等效单自由体系
质量传递系数
荷载传递系数
petrochemical control room antiknock design equivalent single freedom system mass transfer coefficient load transfer coefficient