低配筋剪力墙双边抗震加固试验研究 被引量:3

Experimental Study on Both Sides Strengthening of Low-reinforced Shear Wall
下载PDF
导出
摘要 北京前三门地区有一些建于上个世纪70年代的鱼骨式剪力墙混凝土建筑。该建筑修建时间较早,受经济与技术条件限制,剪力墙混凝土强度低,配筋率不满足现行建筑抗震规范要求。北京市建筑设计研究院提出了外套式加固方案,该方案具有不入户,节能保温,增大使用面积等优点。为了检验外套式加固方案的性能,本文设计了2个双边加固剪力墙试件与2个未加固试件,对其进行了拟静力试验研究。试验结果表明,加固后墙体承载力明显提高,加固后墙体具有良好的延性。 A group of reinforced concrete buildings which were constructed during 1970s are still used in Qiansanmen area of Beijing. The structure form of these buildings is fishbone shear wall. Limited by the economic and technical conditions, the strength of concrete and reinforcement ratio does not meet the requirements of current seismic code for building structures. A reinforcement method is proposed by Beijing Architecture Design Research Institute, which strengthened the structures from the building outside. This method has some advantages e. g. shortening construction period and enlarging the house area. To investigate the effectiveness of the strengthening method, two strengthened shear walls and two original shear walls are tested in this study. The test results show that the low-reinforced shear walls strengthened from both sides exhibit much higher strength than before, and the ductility is significantly improved.
出处 《工程抗震与加固改造》 北大核心 2013年第5期55-60,共6页 Earthquake Resistant Engineering and Retrofitting
基金 "十二五"国家科技计划课题(2011BAJ08B05 2011BAJ06B03) 国家自然科学基金面上项目(51178250) 北京市建委课题"前三门低配筋剪力墙结构抗震加固技术综合研究"
关键词 低配筋 剪力墙 双边加固 拟静力试验 low reinforcement ratio shear wall exterior strengthen method two sides strengthening quasi-static tests
  • 相关文献

参考文献7

二级参考文献59

共引文献142

同被引文献11

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部