期刊文献+

基于方差分析法的中庭机械排烟影响因素 被引量:1

Variance analysis of influential factors on atrium mechanical exhaust system
原文传递
导出
摘要 通过数值模拟研究与方差分析相结合的方法,分析了火源功率、补风风速、排烟口数量和排烟口位置对中庭机械排烟效果影响的显著性.针对目前国内中庭,根据不同形状系数对中庭进行分类分析,讨论火源功率、补风风速、排烟口数量等不同因素对中庭机械排烟效果影响的显著程度.得出了不同形状系数的中庭机械排烟效果影响因素显著性的排序,其中火源功率对中庭内的温度影响最大,而补风风速对中庭底部温度的影响较大,排烟口数量和布置情况对中庭顶部温度影响大.中庭内烟气层的高度受补风风速和火源功率影响显著. Using numerical simulation and variance analysis, the influences of the heat release rate, make-up air velocity, number of smoke vent, and smoke vent position on atrium mechanical exhaust system are analyzed. Dif- ferent shape factors cause different significant effect order. Heat release rate is the primary influential factor on temperature in atrium. Makeup air velocity has significant effect on temperature in bottom part of atrium. For the top of atrium, number of smoke vent and its position influence temperature obviously. Makeup air velocity and heat release rate have significant effect on smoke layer height in atrium.
出处 《武汉大学学报(工学版)》 CAS CSCD 北大核心 2013年第5期640-644,共5页 Engineering Journal of Wuhan University
关键词 机械排烟 数值模拟 方差分析 火源功率 补风 排烟口 影响显著性 mechanical exhaust numerical simulation variance analysis heat release rate make-up airsmoke vent influence significance
  • 相关文献

参考文献5

  • 1McGRATTAN K. Fire Dynamics Simulator (Version 4), Technical Reference Guide [M]. National Institute of Standards and Technology, Gaithersburg, Mary- land, July 2004.
  • 2中华人民共和国公安部.GB50045-95高层民用建筑设计防火规范(2005版)[S].北京:中国计划出本社,2005.
  • 3National Fire Protection Association. NFPA92B Guide for Smoke Management Systems in Malls, Atria, and Large Areas [S]. Quincy, MA, Us The Standards Counci, 1995.
  • 4陈颖,李思成,张靖岩,李开源.补风速度对中庭类建筑机械排烟效果的影响[J].暖通空调,2011,41(5):72-74. 被引量:13
  • 5杨合,詹梅.材料加工过程实验建模方法[M].西安:西北工业大学出版社,2008.

二级参考文献11

  • 1中华人民共和国公安部.GB50045-95高层民用建筑设计防火规范(2005年版)[S].北京:中国计划出版社,2005
  • 2Tanaka T, Yamana T. Smoke control in large scale spaces(part 1) E.I-]. Fire Science and Technology, 1985,5(1) :31-40.
  • 3Milke J A. Smoke management for covered malls and atria[J]. Fire Technology, 1990,26 (3) : 223- 243.
  • 4Milke J A, Mowrer F W. A design algorithm for smoke management systems in atria and covered malls[R]. Maryland: University of Maryland College Park, 1993.
  • 5Hadjisophocleous G V, Lougheed G D. Experimental and numerical study of smoke conditions in an atrium with mechanical exhaust[J]. International Journal on Engineering Per{ormance-Based Fire Codes, 1999, 1 (3):183-187.
  • 6Klote J H. An overview of atrium smoke management [J].Fire Protection Engineering, 2000 (7):24-34.
  • 7Klote, J H. Method of predicting smoke movement in atria with application to smoke management[R]. Gaithersburg, Maryland. National Institute of Standards and Technology, 1994.
  • 8李思成,陈颖,陈兴,等.中庭机械排烟不同补风量效果数值模拟[C]//第五届消防性能化与消防工程研讨会.广州,20lO.
  • 9National Fire Protection Association. NFPA92B Guide for smoke management systems in malls, atria, and large areas[S]. Quincy, MA, US: The Standards Counci, 1995.
  • 10Kevin McGrattan. Fire Dynamics Simulator (Version 4) Technical Reference Guide [ M ]. Maryland: National Institute of Standards and Technology, 2005.