摘要 文章为考察外套预制加固法中螺栓连接节点的抗震性能设计了4组拟静力试验,分别考察预埋螺栓连接的预制剪力墙片抗弯、抗剪性能,得出了试验体的强度、刚度、延性和耗能性能参数。试验结果表明:墙片的滞回曲线比较饱满,承载力接近极限时出现捏拢现象。螺栓连接件能够充分传递竖向应力和剪力,将预制剪力墙片连接成一个整体。型钢边缘构件可以有效地增加构件的延性和耗能能力,各构件承载力突降前位移角至少达到2%。 The seismic behavior of four pieces of precast cantilever RC walls with bolted connections is examined by quasi-static tests. The strength, the stiffness, the ductility and the energy dissipation capacity of these specimens are evaluated from the experimental results. It is demonstrated that the hysteresis loops of pre-cast walls with bolted connections are fat and pinching was observed when the maximum bearing capacity is approached. The bolted con- nection is deemed sufficient to transfer both vertical and horizontal forces between wall pieces. The embedded steel boundary element offers the wall pieces good ductility and energy dissipation capacity. All specimens reach at least 2% drift before significant strength degradation occurrs.
出处 《地震工程与工程振动》 CSCD 北大核心 2013年第5期167-175,共9页 Earthquake Engineering and Engineering Dynamics
基金 地震行业科研专项经费资金项目(201108006)
关键词 预制剪力墙 型钢混凝土 螺栓连接键 抗震性能 拟静力试验 :pre-cast shear wall steel reinforced concrete bolted connection seismic behavior quasi -static test
  • 相关文献

参考文献10

二级参考文献33

  • 1陈海波,何长华,李振福,邢海军.钢管结构无加劲法兰计算方法的试验研究[J].电力建设,2005,26(7):16-19. 被引量:21
  • 2规程JGJ82编制组.JGJ82征求意见稿:钢结构高强度螺栓连接技术规程[S].2006.
  • 3杨振国.轻型法兰的弹性应力计算.华东化工学院学报,1986,12(6):799-804.
  • 4GB50011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.
  • 5JG儿01-96建筑抗震试验方法规程[s].北京:中国建筑工业出版社,1996.
  • 6孙金樨,张美励,苏文元.整体装配式剪力墙体系的连接构造和抗震性能:一种新型装配式大板结构[R].北京:北京市建筑设计研究院,1986.
  • 7GB50010-2002.混凝土结构设计规范[S].[S].,..
  • 8GB50011-2001.建筑抗震设计规范[S].[S].,..
  • 9JGJ101-96.建筑抗震试验方法规程[S].[S].,..
  • 10万墨林 曾兵.大板结构接缝的强度和刚度[J].建筑结构学报,1986,(4):54-68.