期刊文献+

光纤过程检测硫酸亚铁缓释片释放度 被引量:1

Fobre Optical Test the Release of Ferrous Sulfate Sustained Release Tablets
原文传递
导出
摘要 建立光纤药物溶出度实时测定仪(FODT)在线监测硫酸亚铁溶出度测定的新方法。研究发现通过络合反应检测Fe2+是可行的,FODT测定硫酸亚铁缓释片释放度与AAS测定结果无统计学意义。利用FODT过程检测硫酸亚铁缓释片释放度,全面直观地反映了药品的释放过程和内在质量,较经典方法能提供更多信息,测定过程简便自动,测定结果准确可靠。 A new method was established which can on-line monitor the release rate of ferrous sulfate tablets. Study found that by complexation reaction for detection of Fe^2+ is feasible. There are no statistical significance between FODT and atomic absorption spectrometry to detect release rate of ferrous sulfate tablets. Use FODT process detects release rate of ferrous sulfate tablets directly reflects the overall,drug release process and internal quality, compared with the classic method can provide more information, automatic measurement process is simple, accurate and reliable measurement results.
出处 《光谱实验室》 CAS 2013年第6期3292-3295,共4页 Chinese Journal of Spectroscopy Laboratory
基金 新疆维吾尔自治区自然科学基金项目 2012211A025
关键词 硫酸亚铁缓释片 光纤药物溶出度实时测定仪 释放度 Ferrous Sulfate Sustained Release Tablets Fiber-optic Dissolution Test System Release
  • 相关文献

参考文献2

二级参考文献9

  • 1R·A·小戴 A·L·安德伍德.定量分析[M].上海:上海科学技术出版社,1980.352-353.
  • 2小戴 R A,定量分析,1980年,352页
  • 3Morihara M, Aoyagi N, Kaniwa N, et al. Assessment of gastric acidity of Japanese subjects over the last 15 years [J]. Biol Pharm Bull, 2001, 24 (3): 313-315.
  • 4薛大全 高鸿慈 张先洲.实用片剂制备指南[M].湖北:武汉出版社,2000.329-330.
  • 5日本厚生省医藥安全局謇查管理課.後発医藥品の生物学的同等性試験ガィドラィンにっぃて[M].日本医藥謇第487号[M].,1997-12-22..
  • 6日本厚生省医藥安全局謇查管理課.仿制药品的生物等效性研究指导原则医药[M].第487号[M].,1997-12-22..
  • 7陈晓嫒.从生物等效性研究中存在的问题谈如何提高我国已有国家标准药品的质量[N].中国医药报,2004-01-08.
  • 8夏锦辉,刘昌孝.固体药物制剂的体外溶出度的统计学评价分析[J].中国药学杂志,2000,35(2):130-131. 被引量:107
  • 9瞿发林,丁青龙,殷强.舒必利片溶出度考察[J].中国医院药学杂志,1991,11(5):209-211. 被引量:3

共引文献125

同被引文献8

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部