期刊文献+

Use of Double Differential-mode Current Injection Method Equivalent to High Level Illumination for Susceptibility Testing 被引量:3

Use of Double Differential-mode Current Injection Method Equivalent to High Level Illumination for Susceptibility Testing
下载PDF
导出
摘要 To achieve the electric field strength and the induced currents in equivalence in susceptibility tests with the high-level field radiation above 400 MHz,a double differential-mode(DM) current injection method based on directional couplers is proposed.Two cascaded symmetrical directional couplers compose a coupling device to inject the DM currents.When the coupling device is used,two devices are necessary to achieve the equivalence between radiation and injection,i.e.the equivalence between the injected voltages and the field strength,which is linear,regardless of the characteristics of the equipment under test(EUT).The results are verified by experiments using typical coaxial cables and nonlinear devices,where the equivalence between the nonlinear EUT responses induced by radiation and injection at both ends is achieved by using two coupling devices.At a frequency up to 1.75 GHz,the maximal experimental error is only 3.39%.The experimental results confirm the accuracy of the proposed method even both the EUTs work in the nonlinear region.The proposed method is applicable for radiated susceptibility(RS) testing of interconnected systems in the microwave frequency band. To achieve the electric field strength and the induced currents in equivalence in susceptibility tests with the high-level field radiation above 400 MHz, a double differential-mode (DM) current injection method based on directional couplers is proposed. Two cascaded symmetrical directional couplers compose a coupling device to inject the DM currents. When the coupling device is used, two devices are necessary to achieve the equivalence between radiation and injection, i.e. the equivalence between the injected voltages and the field strength, which is linear, regardless of the characteristics of the equipment under test (EUT). The results are verified by experiments using typical coaxial cables and nonlinear devices, where the equivalence between the nonlinear EUT responses induced by radiation and injec- tion at both ends is achieved by using two coupling devices. At a frequency up to 1.75 GHz, the maximal experimental error is only 3.39%. The experimental results confirm the accuracy of the proposed method even both the EUTs work in the nonlinear region. The proposed me- thod is applicable for radiated susceptibility (RS) testing of interconnected systems in the microwave frequency band.
出处 《高电压技术》 EI CAS CSCD 北大核心 2013年第10期2431-2437,共7页 High Voltage Engineering
基金 supported by National Basic Research Program of China(973 Program)
关键词 电流注入法 药敏试验 差模 定向耦合器 非线性器件 照明 实验误差 电场强度 double current injection differential-mode radiated susceptibility directional coupler interconnected systems bulk currentinjection
  • 相关文献

参考文献6

二级参考文献49

共引文献88

同被引文献45

引证文献3

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部