期刊文献+

正畸综合治疗台不同出水时段水路细菌污染的动态监控 被引量:3

下载PDF
导出
摘要 目前,口腔综合治疗台所用水源以及手机使用停止后回吸造成的水及水道内壁的污染,在口腔临床中广泛存在,已成为一个重要交叉污染源[1]。美国牙科协会和国际疾病控制中心建议牙医每天接诊第1名患者,冲洗管道2-3mni,每两名患者之间冲洗20-30s,以有利于去除治疗过程中回吸进入牙科水道的细菌,预防交叉感染[2]。
作者 陈晓春 李琳
机构地区 广东省口腔医院
出处 《江西医药》 CAS 2013年第1期21-23,共3页 Jiangxi Medical Journal
基金 广东省科技计划(2010B080701049)
  • 相关文献

参考文献5

二级参考文献20

  • 1[2]Ojajarvi J. Prevention of microbial contamination of dental unit caused by suction into the turbine drive air lines[J]. Oral Surg Oral Med Oral Pathol, 1996, 81(1): 50-52.
  • 2[3]Checchi L, Montebugnoli L, Samaritani S. Contamination of the turbine air chamber: a risk of cross infection[J]. J Clin Periodontal,1998, 25(8):607-511.
  • 3[4]Samranayake LP. Essential microbiology for dentistry[M]. New York:Churchill Livingstone, 1996:155.
  • 4[5]Foley FE, Gutheim RN. Serum hepatitis following dental procedures: a presentation of 15 cases, including three fatalities[J]. Ann Int Med,1956,45(3): 369-380.
  • 5[6]Legnani P, Checchi L, Pelliccioni GA, et al. Atmospheric contamination during dental procedures[J]. Quintessence Iht, 1994,25(6) :435-439.
  • 6[7]Araujo MW, Andreana S. Risk and prevention of transmission of infectious diseases in dentistry[J]. Quintessence Iht, 2002, 33 (5): 376-382.
  • 7Dolci G,Lucio M.Cross-contamination in Dentistry[J].Journal of Dental University Industries Association,2001;18:11.
  • 8陶根惠,李云川.提高护理人员应用计算机技能的思考与实践[J]医学信息,2001(02).
  • 9关旭明,钟宝华,付丽华.利用计算机网络系统实现护理信息交流[J].护理研究,2001,15(1):42-43. 被引量:8
  • 10郜慧芬.计算机在我国医院护理管理中的应用现状[J].护理研究,2001,15(2):111-111. 被引量:7

共引文献41

同被引文献36

  • 1O'Donnell MJ,Boyle MA,Russell RJ,et al.Management of dental unit waterline biofilms in the 21st century[J].Future Microbiol,2011,6(10):1209-1226.
  • 2Coleman DC,O'Donnell MJ,Shore AC,et al.The role of manufacturers in reducing biofilms in dental chair waterlines[J].J Dent,2007,35(9):701-711.
  • 3Scheid RC,Kim CK,Bright JS,et al.Reduction of microbes in handpieces by flushing before use[J].J Am Dent Assoc,1982,105(4):658-660.
  • 4Mayo JA,Oertling KM,Andrieu SC.Bacterial biofilm:a source of contamination in dental air-water syringes[J].Clin Prev Dent,1990,12(2):13-20.
  • 5Williams HN,Baer ML,Kelley JI.Contribution of biofilm bacteria to the contamination of the dental unit water supply[J].J Am Dent Assoc,1995,126(9):1255-1260.
  • 6Dallolio L,Seuderi A ,Rini M S ,et al. Effect of different disinfec- tion protocols on microbial and biofilm contamination of dental u- nit waterlines in community dental practices [ J ]. Int J Environ Res Public Health,2014,11(2) :2064 -2076.
  • 7Gungor ND, Kadaifciler DG, Peker OO. Investigation of the bac- terial load and antibiotic susceptibility of dental units[ J]. Envi- ron Monit Assess .2014.186( 3 ), 1847 - 1853.
  • 8Kadaifciler DG, Okten S, Sen B. Mycological contamination in dental unit waterlines in Istanbul, Turkey [ J]. Braz J Microbiol, 2013,44(3) :977 -981.
  • 9朱笠,梁玉红,邹梅.医院口腔综合治疗台诊疗用水污染状况调查[J].中国消毒学杂志,2008,25(1):81-82. 被引量:20
  • 10邹梅,梁玉红,石淑琴,朱笠.口腔科综合治疗台治疗用水污染调查[J].预防医学情报杂志,2008,24(9):729-730. 被引量:4