非均匀组织中光子剂量分布的MC模拟研究

Monte Carlo simulation of photon dose distribution in inhomogeneous tissues
下载PDF
导出
摘要 放疗计划系统中的光子剂量计算一般先基于均匀水模进行,然后根据人体组织密度的非均匀性,利用修正算法,将均匀水模的剂量分布修正到真实人体.在不同组织交界面处,非均匀修正的精度较差.本研究利用蒙特卡洛程序对人体非均匀组织的几种组合情况进行模拟,获得非均匀组织对光子吸收剂量的影响,为发展精确的剂量修正方法提供基础. The general calculation method of photon dose distribution in a radiation therapy planning system is carried out based on the homogeneous water phantom. The actual dose distribution on the human body is obtained by the correction algorithm according to the inhomogeneous characteristic of tissue density. The correction precision is low in the different tissue interfaces. The combinations of human inhomogeneous tissue are simulated with Monte Carlo program in this study, the influence of photon absorbed dose in the different tissue interfaces are obtained, which provides a foundation for the development of an accurate correction method for photon dose distribution.
出处 《中国科学技术大学学报》 CAS CSCD 北大核心 2013年第10期856-860,共5页 JUSTC
基金 国家自然基金(60872112 10805012) 安徽省自然基金(11040606M132)资助
关键词 MC 非均匀组织 光子 剂量分布 Monte Carlo inhomogeneous tissue photon dose distribution
  • 相关文献

参考文献7

  • 1李国丽,周金斌,林辉,景佳,等.基于MonteCarlo模拟的快速有限笔束算法研究[J].中国科技大学学报,2009,39(5):515-519.
  • 2International Commission on Radiation Units and Measurements. Determination of Absorbed Dose in a Patient Irradiated by Beams of X or Gamma Rays in Radiotherapy Procedures[R]. Report 24, Washington, 1976.
  • 3du Plessis F C, Willemse C A, L6tter M G, et al. Comparison of Batho, ETAR and Monte Carlo dose calculation method in CT based patient methods [J]. Medical Physics, 2001, 28(4):582-589.
  • 4王志远,李树祥,吕庆文,史亚军.一种基于CT值进行组织不均匀性剂量校正的快速算法[J].中国医学物理学杂志,2002,19(2):94-95. 被引量:8
  • 5宋钢,李国丽,吴爱东,陈义学,吴宜灿,孔令玲,唐虹,汪志.基于混合Batho修正的RBM剂量计算方法在仿真头模实验中的剂量学验证[J].原子核物理评论,2006,23(2):246-249. 被引量:8
  • 6Walters B, Kawrakow I, Rogers D W O. DOSXYZnrc Users Manual [P]. National Research Council of Canada Report PIRS-794revB, Ottawa, 2011.
  • 7LI G, Yan B, Wu A, et al. The comparative research of Monte Carlo simulation based inhomogeneous tissue correction algorithm [J ]. Medical Physics, SU-E-T- 373, 2012, 39(6): 3 790.

二级参考文献20

  • 1吴宜灿,李国丽,陶声祥,吴爱东,孔令玲,刘伯学,林大全,陈义学,宋钢,赵攀,林辉,陈朝斌,黄群英,吴李军.精确放射治疗系统ARTS的研究与发展[J].中国医学物理学杂志,2005,22(6):683-690. 被引量:44
  • 2赵攀,陈义学,林辉,郑善良,吴宜灿.MCNP/MCNPX几何栅元划分方法对精确放疗剂量计算的影响研究[J].原子核物理评论,2006,23(2):258-262. 被引量:13
  • 3[1]Faiz M Khan. The Physics of Radiation Therapy (second edition)[M]. 1992.286-299.
  • 4[2]John W. Wong, James A. Purdy. On methods of inhomogeneity corrections for photon transport[J]. Medical Physics, 1990, 17(5):807-814.
  • 5[3]F.C.P. du Plessis, C.A.Willemse, et al. Comparison of the Batho,ETAR and Monte Carlo dose calculation methods in CT based patient methods[J]. Medical Physics,2001,28(4):582-589.
  • 6[4]J.R.Cunningham. Tissue Inhomogeneity Corrections in Photon-Beam Treatment Planning in Progress in Modern Radiation Physics [M]edited by C.G.Orton (Plenum, New York),1982:103-131.
  • 7[5]Batho HF. Lung corrections in cobalt 60 beam therapy[J]. Journal of Cancer Association of Radiology, 1964,15:79-83.
  • 8[6]M.R.Sontag, J. R. Cunningham. Corrections to absorbed dose cal culations for tissue inhomogeneities[J]. Medical Physics, 1977,4:431-436.
  • 9[7]S. Webb, R. A. Fox. Verification by Monte Carlo methods of a power law tissue-air ratio algorithm for inhomogeneity corrections in photon beam dose calculations[J]. Physics in Medicine and Bi-ology, 1980,25:225 -240.
  • 10[8]K J Cassell, Pauline A Hobday, et al. The implementation of a generalized Batho inhomogeneity correction for radiotherapy plan-ning with direct use of CT numbers[J]. Physics in Medicine and Biology,1981,26(4):825-833.

共引文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部