期刊文献+

每搏变异度在胸外科手术中的应用 被引量:1

下载PDF
导出
摘要 血流动力学监测是术中麻醉管理的重要组成部分,合理适度的容量负荷有利于术中血流动力学的稳定,维持良好的组织灌注,避免肺水肿等不良事件发生。每搏变异度(SVV)作为近年来监测血流动力学的一项重要指标,可准确监测机械通气患者血容量变化,指导液体治疗。本文将对每搏变异度做一综述。
出处 《浙江创伤外科》 2013年第5期761-762,共2页 Zhejiang Journal of Traumatic Surgery
  • 相关文献

参考文献23

  • 1Gan TJ, Soppitt A, Maroof M, et al. Goal- directed intraoperative fluid administration reduces length of hospital stay after major surgery[J]. Anesthesiology, 2002, 97: 802- 826.
  • 2Rex S, Brose S, Metzelder S, et al. Pre- diction of fluid responsiveness in patients during cardiac surgery [J]. Br J Anaesth, 2004, 93: 782-788.
  • 3Paul E, Marik, Rodrigo C, Tajender V, et al. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A sys- tematic review of the literature [J]. Crit Care Med, 2009, 37: 2642-2647.
  • 4Michard F. Changes in Arterial Pressure During Mechanical Ventilation [J]. Anes- thesiology, 2005, 103:419-428.
  • 5M.Biais, O. Bernard, J.C. Ha, C. et al. A- bilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery [J]. British Journal of Anaesthesia, 2010, 104: 407-413.
  • 6Cannesson, M; Musard, H; Desebbe, O, et al. The ability of stroke volume variations obtained with vigileo/flotrac system to monitor fluid responsiveness in mechni- cally ventilated patients[J]. Anesthesia and analgesia, 2009, 108: 513-517.
  • 7Heenen S, De Backer D, Vincent. How can the response to volume expansion in patients with spontaneous respiratory movements be predicted [J]. Crit Care, 2006, 10: R102.
  • 8Perner A, Faber T. Stroke volume variation dose not predict fluid responsiveness in patients with septic shock on pressure support ventilation [J]. Acta Anaesthesiol Scand, 2006, 50: 1068-1073.
  • 9Rennet, E. Cavus, P. Meybohm, P. el al. Stroke volume variation during hemor- rhage and after fluid loading?:impact of different tidal volmnes[J]. Acta Anaesthe- siol Scand, 2007, 51: 538-544.
  • 10Hofer CK, Muller SM, Furrer L, et al. Stroke volume and pulse pressure varia- tion for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting [J]. Chest, 2005, 128: 848-854.

二级参考文献9

  • 1Lichtwarck-Aschoff M, Zeravik J, Pfeiffer U J. Intrathoracic blood volume accurately reflects circulatory volume status in critically ill patients with mechanical ventilation. Intensive Care Med, 1992, 18: 142-147.
  • 2Pinsky M R. Functional hemodynamic monitoring. Intensive Care Med, 2002, 28.. 386-388.
  • 3Reuter D A, Bayerlein J, Goepfert M S, et al. Influence oI tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients. Intensive Care Med, 2003, 29: 476-480.
  • 4Wiesenack C, Fiegl C, Keyser A, et al. Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients. Eur J Anaesthesiol, 2005, 22: 658-665.
  • 5LorsomradeeS, Lorsomradee S, Cromheecke S, et al. Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform. J Cardiothorae Vase Anesth, 2007, 21: 636-643.
  • 6Felbinger T W, Goepfert M S, Goresch T, et al. Accuracy of pulse contour cardiac index measurements during changes of preload and aortic impedance. Anaesthesist, 2005, 54: 755-762.
  • 7Manecke G R Jr, Auger W R. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration. J Cardiothorac Vasc Anesth, 2007, 21:3-7.
  • 8宋玉芳,田春芳,曹芳.开胸手术患者单肺通气过程中呼吸参数变化对气道压的影响[J].山东医药,2009,49(11):69-69. 被引量:3
  • 9秦海庆,赵如明,邹学超,刘继.单肺通气安全时限的临床研究[J].上海医学,2001,24(12):756-757. 被引量:3

共引文献15

同被引文献13

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部