摘要 以鲁米诺还原纳米银作为信号分子标记癌胚抗原(CEA),结合具有良好生物相容性的纳米金,固定癌胚抗原抗体于金电极上,成功建立了用于检测人血清中CEA含量的电化学发光(ECL)免疫分析方法。利用该方法可在浓度为0.1-50ng·mL-1的线性范围内稳定监测人血清中CEA的含量,检测限为0.05ng·mL-1。将该电化学发光传感器应用于健康志愿者的血清中进行CEA的检测,结果令人满意。相对标准偏差小于7.2%,平均回收率为97.2-102.9%,具有良好的稳定性和重现性。 Electrochemiluminescence immunoassay for the determination of carcinoembryonic antigen (CEA) was created with nanosilver as the signal molecule labeled on CEA and with nanogold to fix anti- CEA on gold electrode. This method can be used to determine the content of CEA in human serum within a linear range of 0.1-50ng.mL-1 with a LOD (limit of detection ) of 0.05ng-mL^-1. The electroehemiluminescence immunosensor has been successfully applied in the determination of CEA in the serum of healthy volunteers. The RSD has been lower than 7.2%, and the average recovery rate has been 97.2-102.9%, which shows the sensor's good stability and reproducibility.
作者 赵易 姚武
出处 《黄山学院学报》 2013年第5期40-42,共3页 Journal of Huangshan University
基金 安徽省自然科学基金面上项目(11040606M41) 安徽省教育厅自然科学研究项目(KJ2010B215) 安徽省教育厅教学研究项目(20100997) 黄山学院人才培养模式创新实验区项目(2010SYQ01)
关键词 癌胚抗原 纳米银 电化学发光 免疫传感器 ECL nanosilver CEA immunosensor
  • 相关文献

参考文献12

  • 1Shen GY, electric Wang H, Deng munosensor for T, Shen GL, Yu RQ. A novel piezo- detection of carcinoembryonic antigen [J]. Talanta, 2005, 67 (1) : 217-220.
  • 2Schneider J. Tumor markers in detection of lung cancer [J].Adv. Clin.Chem., 2006, 42, 1-41.
  • 3Wu J, Yan F, Zhang XQ, Yan YT, Tang JH, Ju HX. Disposable reagentless electrochemical immunosensor array based on a biopolymer/sol-gel membrane for simultaneous measurement of several tumor markers [J]. Clinical Chemistry, 2008, 54(9): 1481- 1488.
  • 4Dutra RF, Mendes RK, Lins da Silva V, Kubota LT. Surface plasmon resonance immunosensor for human cardiae troponin T based on self-assembled mouolayer [J]. J Pharm. Biomed. Anal., 2007, 43(5): 1744-1750.
  • 5Rowe CA, Scruggs SB, Feldstein MJ, Golden JP, Ligler FS. An array im-munosensor for simulataneous detections of clinical ana- lytes [J]. Anal. Chem., 1999, 71(2): 433-439.
  • 6Yang MH, Kostov Y, Bruck HA, Rasooly A. Carbon nanotubes with enhanced chemil immunoassay detection of staphylococcal enterotoxin B in food 2008, 80(22): 8532-8537. for CCD-based [J]. Anal. Chem.
  • 7Mohammadnejad J, Rasaee MJ, Babaei MH, Paknejad M, Hasan ZM, Salouti M, Gandomkar M, Sadri K. Radioimmunotherapy of MCF7 breast cancer cell line with 131I-PR81 monoclonal anti- body against MUCI: comparison of direct and indirect radioiodi- nation methods [J]. Hum. Antibodies, 2010, 19(1): 15-25.
  • 8Gui WJ, Jin MJ, Sun LF, Guo YR, Zhu GN. Residues determination of carbofuran in vegetables based on sensitive time- resolved fluorescence immunoassay [J]. Food Agric. Immunol., 2009, 20( 1): 49-56.
  • 9Yuan JL, Wang GL, Majima K, Matsumoto K. Synthesis of a new terbium fluorescent chelate and its application to time-resolved fluoroimmunoassay [J]. Anal. Chem., 2001, 73, 1869-1876.
  • 10Cheng YF, Yuan R, Chai YQ, Niu H, Cao YL, Liu HJ, Bai LJ, Yuan YL. Highly sensitive luminol electrochemil based on ZnO nanoparticles and glucose oxidase decorated graphene for cancer biomarker detection [J]. Analytica Chimica Acta, 2012,745:137-142.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部