期刊文献+

建筑外墙外保温系统防水处理分析 被引量:1

Waterproof Treatment and Analysis for External Thermal Insulation System
下载PDF
导出
摘要 在分析了建筑外墙外保温系统常存在的饰面层开裂渗漏、门窗洞口渗漏等主要问题后,详细介绍了处理保温系统节点防水的配件,以及外保温系统墙体门窗、穿墙管洞口的节点防水处理方法,并介绍了以石墨改性膨胀聚苯板为主材的外保温系统,该系统兼具保温、防火、防水功能。 Based on analyses of some main problems of external thermal insulation system, including cracks and leakage of finishing layer and leakage of window and door openings, the article describes the accessories for nodes waterproofing of insulation system and node waterproofing treatment for external insulation system such as windows, doors and wall pipe holes. It also introduces the exterior insulation system using graphite modified polystyrene board as main material, which is thermal insulation, fireproof and waterproof.
出处 《中国建筑防水》 2013年第21期40-42,共3页 China Building Waterproofing
关键词 建筑外墙 外保温系统 石墨改性膨胀聚苯板 防水 节点 building external wall exterior insulation system graphite modified expanded polystyrene board waterproof [lode
  • 相关文献

参考文献2

  • 1徐州卧牛山新型防水材料有限公司.Q/320301QAGl9-2012石墨改性膨胀聚苯板[S].2012.
  • 2全国消防标准化技术委员会.GB8624-2006建筑材料及制品燃烧性能分级[S].北京:中国标准出版社,2007.

同被引文献4

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部