阐述了ME5000测距仪校准测距基线的方法和校准结果的各项改正公式,分析了其校准测距基线测量结果的测量不确定度,证明了ME5000校准测距基线的可行性。
An introduction is given on the calibration method and correction formula of results for ME5000 distance meter calibrating base- line length. Measurement uncertainty is analyzed for calibrating baseline length and its feasibility is verified.
出处
《计测技术》
2013年第5期63-65,共3页
Metrology & Measurement Technology