期刊文献+

关于影响立式金属罐油品静态计量准确性因素的分析 被引量:7

Analysis on Influences of Static Measurement Accuracy of Vertical Metal Tank Oil
下载PDF
导出
摘要 立式金属罐油品静态计量,一般均采用人工检尺法,人工检尺计量存在大量的系统误差和随机误差。本文重点对容量计量环节可能存在的计量误差进行分析,如立式金属罐总容量检定不确定度、液位测量、测深钢卷尺结构变形、参照高度变化、罐体倾斜、上计量基准点模糊等。通过对上述因素的综合分析,给出了提高日常计量准确性、减小计量交接误差的具体建议。 Manual inspecting method is generally used in static measurement of vertical metal tank oil, but it is accompanied with many sys- tem errors and random errors. This paper analyzes the capacity measurement errors, such as the total volume of vertical metal tank, liquid level measurement uncertainty, sounding tape steel structure deformation, reference height changes, tank tilt, upper datum point fuzziness, etc. Based on the comprehensive consideration of these factors, technical methods are offered to improve the daily measurement accuracy and reduce the transfer errors.
出处 《计测技术》 2013年第5期66-69,共4页 Metrology & Measurement Technology
关键词 立式金属罐 静态计量 误差分析 vertical metal tank static measurement error analysis
  • 相关文献

参考文献8

二级参考文献8

  • 1刘子勇,佟明星,王丁,等.JJFl68—2005立式金属罐容量[M].北京:中国计量出版社,2006.
  • 2刘子勇.立式金属罐容量检定全站仪测量方法[M].2007.
  • 3刘子勇.容量检测技术培训教材[M].北京:中国计量科学研究院力学与声学计量科学研究所,2009.
  • 4全站仪原理[M].徕卡全站仪技术手册.
  • 5张良琚.徕卡TPSl000系统[C].测绘学院,1997.
  • 6陈海林,郭毅力.几种全站仪、测距仪测距误差分布的分析[C]//2003年全国测绘仪器综合学术年会论文集.
  • 7徐忠阳.全站仪轴系误差自动修正及其对角度观测的影响[C]//e003年全国测绘仪器综合学术年会论文集.
  • 8安德恭,李洪运,齐维君,等.JJG100—2003全站型电子速测仪[M].北京:中国计量出版社,2004.