通过对湖北安陆棉纺织厂SZL1 0 1 .2 5型锅炉的烟、风道系统进行的空气动力计算与测定 ,提出了改进建议 ,指出在选择引风机时 ,应重视对风机全压的要求。表 3图 3参 3。
By aerodynamically calculating and determining about the flue and duct system of model SZL10\|1.25 boiler of Hubei Anlu textile mill, we put forward an improved proposal and point out that we should take a special attention to the full pressure of the induced fan while selecting it.