期刊文献+

新型水基着色探伤剂的性能研究 被引量:1

Performance of the Novel Water-Based Dye Penetration Inspection Agent
下载PDF
导出
摘要 选用60 g/L的活性艳红作为着色剂,4 mg/L的十二烷基苯磺酸钠作为表面活性剂配制新型水基探伤剂,可达到3级探伤灵敏度.分别采用毛细管爬高、金属板延展、驱赶平衡圈直径和扩延直径等指标对其性能进行研究,并与市售DPT-8型探伤剂进行比较,结果表明,所配制的水基探伤剂具有优良的应用特性,可满足金属部件表面探伤的要求. A novel water-based dye penetration inspect agent is developed by using 60 g/L reactive brilliant red dye and 4 mg/L sodium dodecyl benzene sulfonate ( SDBS ), which can reach level 3 detection sensitivity. The property of the novel water-based dye penetration inspection agent is compared with the commercial DPT-8 penetration inspection agent by means of the capillary action, the diffusion on the metal, the driven diameter and the diffusion diameter. It is shown that a novel water-based dye penetration inspection agent has good performance for the application for the defect detection of the metal workpiece.
出处 《上海电力学院学报》 CAS 2013年第5期485-488,共4页 Journal of Shanghai University of Electric Power
基金 上海市基础研究重点项目(11JC1404400)
关键词 水基着色探伤剂 表面活性剂 染料 灵敏度 water-based dye penetration inspection agent surfactant dye sensitivity
  • 相关文献

参考文献8

二级参考文献25

共引文献41

同被引文献30

  • 1李晓萌,高平.牙科CAD/CAM系统的主要技术构成及研究现状[J].口腔颌面修复学杂志,2005,6(4):299-301. 被引量:13
  • 2Vojdani M, Torabi K, Farjood E, et al. Comparison the Marginal and Internal Fit of Metal Copings Cast from Wax Patterns Fabricated by CAD/CAM and Conventional Wax up Techniques.J Dent.2013;14(3):118-129.
  • 3Fasbinder DJ. Computerized technology for restorative dentistry. Am J Dent 2013;26(3):115-120.
  • 4George FM,Chan HL,Razzoog ME,et al.Fabrication of a cast-based implant surgical guide using guide sleeves.J Prosthet Dent.2011;106(6):409-412.
  • 5Zhao XZ,Xu WH,Tang ZH,et al.Accuracy of computer-guided implant surgery by a CAD/CAM and laser scanning technique.Chin J Dent Res.2014;17(1):31-36.
  • 6Moslehifard E,Nokar S.Designing a custom made gauge device for application in the access hole correction in the dental implant surgical guide.J Indian Prosthodont Soc. 2012;12(2):123-129.
  • 7D'Haese J,Van De Velde T,Komiyama A,et al.Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature.Clin Implant Dent Relat Res. 2012;14(3):321-335.
  • 8Vieira DM,Sotto-Maior BS,Barros CA,et al.Clinical accuracy of flapless computer-guided surgery for implant placement in edentulous arches.Int J Oral Maxillofac Implants.2013;28(5): 1347-1351.
  • 9Duret F, Blouin JL, Duret B.CAD-CAM in dentistry.J Am Dent Assoc. 1988;117(6):715-720.
  • 10Young JM, Altschuler BR.Laser holography in dentistry.J Prothet Dent.1977; 38(2):216-225.

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部