摘要
针对柔性直流输电的特点,分析了柔性直流输电损耗的构成及其计算方法。并在此基础上,结合最新技术发展及对具体参数的计算情况,进一步分析柔性直流输电损耗与直流电压等级的关系,给出了柔性直流输电损耗对其直流电压选择影响情况的初步结论。
Aiming at characteristics of flexible direct current power transmission, this paper analyzes composition of flexible direct current power transmission losses and related calculation method. On above basis and combining newest technology de- velopment and calculation of specified parameters, it analyzes relationship between flexible direct current power transmission losses and direct current voltage level and proposes preliminary conclusion of impact on choosing direct current voltage by flexible direct current power transmission.
出处
《广东电力》
2013年第10期36-40,64,共6页
Guangdong Electric Power
关键词
柔性直流
损耗
直流电压等级
flexible direct current
loss
direct voltage level