电热聚合法对两种树脂基托挠曲强度的影响 被引量:2

Influence of electric-heating polymerlization method on flexural strength of 2 denture base polymers
下载PDF
导出
摘要 目的研究电热聚合方法对义齿基托挠曲强度的影响。方法选择两种常用热凝义齿基托树脂材料,分别采用传统水浴法和电热聚合法制作样本。样本分组为日进水浴组、贺利氏水浴组、日进电热组、贺利氏电热组,每组10个样本。测量各样本的挠曲强度,并用环境扫描电镜进行断面观察。实验数值采用方差分析,α=0.05。结果各组样本的挠曲强度均符合相关要求,日进电热组的挠曲强度值最大为(93.28±4.80)MPa,与其他3组间差别有统计学意义(P<0.05);而其余3组间的比较均无统计学意义。各组样本断面形态存在明显差别。结论电热聚合方法对义齿挠曲强度并无显著影响,所制作样本均符合国家标准。 Objective To evaluate the influence of the electric-heating polymerlization method on the flexural strength of 2 denture base polymers. Methods Two commonly used thermosetting denture-base resins were selected, and the specimens were prepared by traditional water-bath method or electric-heating method,which were divided into 4 groups:Nissin water-bath group, Heraeus water-bath group, Nissin electric-heating group and Heraeus electric-heating group (n = 10). The flexural strength of speciemens in each group was evaluated. The sections of specimens were observed with environment scanning electron microscope. The data were dealt with by analysis of variance,α = 0.05. Results The flexnral strength of each speciemen fulfilled the requirement of Chinese Pharmaceutical industry Standards YY0270-2003. The maximal flexural strength of Nissin speciemens prepared by electric-heating polymerlization [ (93.28 ± 4.80) MPa] had significant differences with the other 3 groups( P 〈 0.05 ). At the same time,there was no significant difference among the other 3 groups. But there were obvious differences among 4 groups in the morphology of sections. Conclusions There was no signif- icant influence of the electric-heating polymerlization method on the flexural strength of the denture base polymers. The flexural strength of all the speciemens fulfilled the Standards YY0270-2003.
出处 《口腔医学》 CAS 2013年第10期697-700,共4页 Stomatology
基金 杭州市科技局卫生专项项目(20100633B06)
关键词 基托聚合方法 电热聚合法 挠曲强度 环境扫描电镜 denture polymerlization method electric-heating polymerlization method flexural strength ESEM
  • 相关文献

参考文献16

  • 1陈志清.口腔材料学[M].4版.北京:人民卫生出版社,2008:21-22.
  • 2Lee HH, Lee CJ, Asaoka K. Correlation in the mechanical prop- erties of acrylic denture base resins [ J ]. Dent Mater J, 2012,31 (1) :157 -164.
  • 3Zappini G, Kammann A, Wachter W. Comparison of fracture tests of denture base materials [ J ]. J Prosthet Dent,2003,90 ( 6 ) : 578 -585.
  • 4Pfeiffer P,Rolleke C,Sherif L. Flexural strength and moduli of hy- poallergenie denture base materials [ J ]. J Prosthet Dent,2005,93 (4) :372 - 377.
  • 5Machado C, Sanchez E, Azer SS, et al. Comparative study of the transverse strength of three denture base materials [ J]. J Dent, 2007,35(12) :930 -933 .
  • 6Bentaher HA, Juszezyk AS, Deb S, et al. Flexural strength and degree of polymerization of a proprietary denture base acrylic resin designed to be cured using long or short cycles [J]. Eur J Prosth- odont Restor Dent,2012,20(4) :163 - 167.
  • 7Jadhav R, Bhide SV, Prabhudesai PS. Assessment of the impact strength of the denture base resin polymerized by various process- ing techniques [ J ]. Indian J Dent Res,2013,24 ( 1 ) : 19 - 25.
  • 8Azzarri M J, Cortizo MS, Alessandrini JL. Effect of the curing condi-tions on the properties of an acrylic denture base resin microwave- polymerised [ J ]. J Dent,2003,31 (7) :463 - 468.
  • 9Kawaguchi T, Lassila LV, Vallittu PK, et al. Mechanical properties of denture base resin cross-linked with methacrylated dendrimer [J]. Dent Mater,2011,27(8) :755 -761.
  • 10Singh RD, Gautam R, Siddhartha R,et al. High performance liq- uid chromatographic determination of residual monomer released from heat-cured acrylic resin. An in vivo study [ J]. J Prosth- odont,2013,22 (5) :358 - 361.

二级参考文献10

  • 1陈志清.口腔材料学[M].4版.北京:人民卫生出版社,2008:36.
  • 2Wong DM, Cheng LY, Chow TW, et al. Effect of processing method on the dimensional accuracy and water sorption of acrylic resin dentures[J]. J Prosthet Dent, 1999, 81(3) : 300 -304.
  • 3Takahashi Y, Chai J, Kawaguchi M. Effect of water sorption on the resistance to plastic deformation of a denture base material re- lined with four different denture reline materials [ J ]. Int J Prosth- odont, 1998, (11) :49 -54.
  • 4Pfeiffer P, Rosenbauer EU. Residual methyl methacrylate mono- mer, water sorption, and water solubility of hypoallergenic denture base materials [J]. J Prosthet Dent, 2004, 92( 1 ) :72 -78.
  • 5Lassila LV, Vallittu PK. Denture base polymer alldent sinomer: mechanical properties, water sorption and release of residual com- pounds [J]. J Oral Rehabil, 2001,28(7) :607 -613.
  • 6Vallittu PK, Miettinen V, Alakuijala P. Residual monomer con- tent and its release into water from denture base materials [ J ]. Dent Mater, 1995, 11 (6) :338 -342.
  • 7Kurata S, Yamazaki N. Synthesis of dimethacryloxyethy 1 - 1,1, 6,6 - tetrahydro - perfluorohexa methylene - 1,6 - dicarbamate as dental base monomers and the mechanical properties of the co- polymers of the monomer and methyl methacrylate [J]. Dent Ma- ter J, 2011, 30(1) :103 -108.
  • 8Jorge JH, GiamPaoIo ET, Maehado AL, et al. Cytotoxicity of den- ture base aerylieresins: literature review [ J ]. J Prosthet Dent, 2003, 90(2) :190 - 193.
  • 9林映荷,邓红颖,巢永烈,李思毅,王波.微波加热法及常规水浴法处理聚甲基丙烯酸甲酯基托材料的性能比较研究[J].华西口腔医学杂志,1999,17(1):75-77. 被引量:9
  • 10蔡玉惠,周国兴,王国平.蒸汽压力机热处理义齿基托材料的实验性研究[J].口腔医学,2001,21(3):125-126. 被引量:2

同被引文献133

  • 1施长溪,陈吉华,刘钢,范冲之.义齿塑料基托热压灌注成形新工艺[J].中华口腔医学杂志,1994,29(4):252-253. 被引量:4
  • 2施长溪,刘钢,陈吉华.多用途牙用树脂聚合器及应用[J].口腔材料器械杂志,1996,5(2):69-71. 被引量:4
  • 3陈治清.口腔材料学[M].北京:人民卫生出版社,2008.
  • 4江铭,江欣,吴景轮,黄城外.义齿基托塑料电热聚合器的研制[J].实用口腔医学杂志,1997,13(2):116-117. 被引量:5
  • 5SweenyWT.Denturebasematerials:Aerylieresins[J].Journal of AmerieanDentalAssoeiation,1939,26:1863-1873.
  • 6WinklerS:Denturebase resin[J].Dental clinics of North American,1984,28:287-297.
  • 7Singh S,Palaskar JN,Mittal S.Comparative evaluation of surface porosities in conventional heat polymerized acrylic resin cured by waterbathand microwave energy with microwavable acrylic resin cured by microwave energy[J].ContempClinDent,2013,4(2):147-151.
  • 8Tuna EB,Rohlig BG,Sancakli E,Evlioglu G,Gencay K.Influence of acrylic resin polymerization methods on residual monomer release[J].J Contemp Dent Pract,2013,14(2):259-264.
  • 9Jadhav R,Bhide SV,Prabhudesai PS.Assessment of the impact strength of the denture base resin polymerized by various processing techniques[J].Indian J Dent Res,2013,24(1):19-25.
  • 10Stafford GD,Bates JE,Hugger R et al.Areviewofthe propertiesof some denture base polymers[J].Journal of Dentistry,1980,8:292.

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部