期刊文献+

超声造影定量参数评价糖尿病患者下肢血流灌注 被引量:1

CEUS quantitative analysis of lower extremity circulation in diabetes patients
下载PDF
导出
摘要 目的探讨CEUS参数在评价糖尿病患者下肢血流灌注中的临床意义。方法对32例糖尿病患者(64条下肢,病例组)和25名志愿者(49条下肢,对照组)进行CEUS检查,定量分析CEUS图像并进行组间对比观察。结果对照组左右侧肢体动静脉通过时间差异无统计学意义,股动静脉通过时间为(10.18±1.33)s,腘动静脉通过时间为(8.42±0.94)s;糖尿病患者股动静脉通过时间为(12.61±2.58)s,腘动静脉通过时间为(10.86±1.89)s,与对照组比较差异有统计学意义(P均<0.001)。结论超声定量分析下肢动静脉通过时间有助于评价糖尿病患者下肢整体微循环。 Objective To explore the application of CEUS parameters in evaluation on microcirculation of lower extremi- ties in patients with diabetes mellitus. Methods Thirty-two diabetes mellitus patients (diabetes group, 64 lower limbs ) and 25 normal volunteers (control group, 49 lower limbs) underwent CEUS. The images were analyzed and compared. Reo suits There was no statistical difference of arteriovenous transit time between left limbs and right limbs in control group. Femoral arteriovenous contrast agent transit time and popliteal arteriovenous contrast agent transit time in control group was (10.18± 1.33) s and (8.42 ± 0. 94) s, respectively, shorter than those in diabetes group ([12. 61±2.58] s and [10.86±1.89]s, both P〈0. 001). Conclusion CEUS quantitative analysis of arteriovenous contrast agent transit time can provide information for evaluating lower extremity microcirculation in patients with diabetes mellitus.
出处 《中国介入影像与治疗学》 CSCD 2013年第11期655-658,共4页 Chinese Journal of Interventional Imaging and Therapy
关键词 超声检查 造影剂 糖尿病 血液灌注 定量分析 Ultrasonography Contrast media Diabetis mellitus Hemoperfusion~ Quantitative analysis
  • 相关文献

参考文献11

  • 1黄品同,张莹,张毅,孔凡雷,叶智敏,翁慧芳,刘美蓉.兔动脉粥样硬化斑块超声造影参数与微血管密度的相关性研究[J].中华超声影像学杂志,2012,21(1):71-74. 被引量:12
  • 2()wen DR, Shalhoub J, Miller S, et al. Inflammation within ca rotid atherosclerotic plaque: Assessment with late phase contrast enhanced US- Radiology, 2010,255(2):638 644.
  • 3魏立亚,何文,项东英,邬冬芳,宁彬,张红霞,田凤兰.超声造影在血管疾病中的应用[J].中国医学影像技术,2008,24(10):1586-1589. 被引量:17
  • 4Clevert DA, Sommer WH, Zengel P, et al. Imaging of carotid ar- terial diseases with contrast enhanced ultrasound (CEUS). Eur J Radiol, 2011,80(1) :68-76.
  • 5Kopp R, Z:rn W, Weidenhagen R, et al. First experience using intraoperative contrast-enhanced ultrasound during endovascular aneurysm repair for infrarenal aortic aneurysms. J Vasc Surg, 2010,51(5) : 1103-1110.
  • 6Clevert DA, Minaifar N, Kopp R, et al. Imaging of endoleaks af ter endovascular aneurysm repair (EVAR) with contrast enhanced ultrasound (CEUS). A pictorial comparison with CTA. Clin Hemorheol Microeirc, 2009,41 (3) : 151-168.
  • 7张瑕,刘宏伟,吕雅赐,黄君,钟兴,邵建立.糖尿病足溃疡超声造影的影像学特点及临床意义[J].南方医科大学学报,2012,32(3):368-370. 被引量:5
  • 8Krix M, Weber MA, Krakowski-Roosen H, et al. Assessment of skeletal muscle perfusion using contrast-enhanced ultrasonogra- phy. J Ultrasound Med, 2005,24(4):431-441.
  • 9Clevert DA, D'Anastasi M, Jung EM. Contrast-enhanced ultra- sound and ruicrocirculation: Efficiency through dynamics-current developments. Clin Hemorheol Microcirc, 2013, 53 (1-2) : 171- 186.
  • 10Lindner JR, Womack L, Barrett EJ, et al. Limb stress-rest per- fusion imaging with contrast ultrasound for the assessment of pe- ripheral arterial disease severity. JACC Cardiovasc Imaging, 2008, 1 (3) :343-350.

二级参考文献30

  • 1岳文胜,尹立雪.颈动脉粥样硬化斑块稳定性的影像学研究进展[J].中华医学超声杂志(电子版),2006,3(6):364-367. 被引量:2
  • 2丁士芳,张运,张梅.颈动脉粥样斑块稳定性与急性脑梗死发病机制关系的临床研究[J].中华超声影像学杂志,2006,15(8):597-600. 被引量:54
  • 3邬冬芳,何文,张红霞,田凤兰,胡向东,项东英,宁彬.颈动脉硬化闭塞症的超声造影研究[J].中华超声影像学杂志,2007,16(5):393-396. 被引量:21
  • 4Mitchell DG. Color Doppler imaging principles, limitations, and artifacts. Radiology, 1990,177(1) : 1.
  • 5Sehiedermaier P, Layer G, Sauerbrueh T. Impactofthecontinuous infusion of Levovist on color Doppler sonography in portal hypertension. AJR Am J Roentgenol, 2002,178(1) :61-65.
  • 6Heiss G, Sharrett AR, Barnes R, et al. Carotid atherosclerosis measured by B-mode ultrasound in populations: associations with cardiovascular risk factors in the ARIC study. Am J Epidemiol, 1991,134(3) :250-256.
  • 7Ophir J, Parker KJ. Contrast agents in diagnostic ultrasound. Ultrasound Med Biol, 1989,15(4) :319-333.
  • 8Ferrer JM, Samso J J, Serrando JR, et al. Use of ultrasound contrast in the diagnosis of carotid artery occlusion. J Vasc Surg, 2000,31 (4) : 736-741.
  • 9Sitzer M. Furst G, Siebler M, et al. Usefulness of an intravenous eontrast medium in the characterization of high-grade internal carotid stenosis with color Doppler-assisted duplex imaging. Stroke, 1994,25(2) :385-389.
  • 10Lsissy JP, Cingualbre A, Loshkajian A, et al. Assessment of deep venos thrombosis in the lower limbs and pelvis: MR venography versus duplex Doppler sonograpy. AJR Am J Roentgenol, 1996,167(4) : 971-975.

共引文献31

同被引文献14

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部