期刊文献+

干粉吸入装置吸入过程中错误操作分析 被引量:2

nalysis on incorrect handling during inhalation with dry powder inhalers
原文传递
导出
摘要 现实生活中,干粉吸入装置错误操作是非常常见的。干粉吸入装置虽然构造各异,但除了启动和关闭步骤不同外,吸入过程的步骤完全相同(包括呼气、含入、吸入、屏气、呼气五部分)。本文详细剖析了干粉吸入装置吸入过程中9步错误操作的内容及正确方法。 Incorrect handling of dry powder inhalers is very common. The structure of dry powder inhalers is different, but steps during inhalation are the same (including exhalation, surround mouthpiece, inhalation, breath-holding, and exhalation) except the difference in initial step and close step. This article analyzes nine steps of incorrect handling during inhaled process and correct method.
作者 李怀东
出处 《国际呼吸杂志》 2013年第20期1594-1596,共3页 International Journal of Respiration
关键词 干粉吸入装置 错误操作 powder inhalers Incorrect handling
  • 相关文献

参考文献23

  • 1史宁,吴久鸿.干粉吸入剂的研究进展[J].中国新药杂志,2007,16(12):922-925. 被引量:21
  • 2Quinet P, Young CA, Heritier F. The use of dry powder inhaler devices by elderly patients suffering from chronic obstructive pulmonary disease. Ann Phys Rehabil Med,2010, 53:69-76.
  • 3Shaikh S. Recent trends in applications of pulmonary drug delivery=a review. Int J Pharm Res Devel,2011,2:17-27.
  • 4Lavorini F, Magnan A, Dubus JC, et aL Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD. Respir Med, 2008,102: 593-604.
  • 5Rootmensen GN, van Keimpema AR, Jansen HM, et al. Predictors of incorrect inhalation technique in patients with asthma or COPD:a study using a validated videotaped scoring method. J Aerosol Med Puim Drug Deliv, 2010,23 : 323-328.
  • 6Galvin WF, Dunne PJ, Kalllstorm TJ. A patient's Guide to Aerosol Drug Delivery. Washington= The American Association for Respiratory Care,2010:52.
  • 7Dolovich MB, Ahrens RC, Hess DR, et al. Device selection and outcomes of aerosol therapy: Evidence-based guidelines: American College of ChestPhysicians/American College of Asthma, Allergy, and Immunology. Chest, 2005,127 : 335- 371.
  • 8Broeders ME, Sanchis J, Levy ML,et al. The ADMIT series - - issues in inhalation therapy. 2. Improving technique and clinical effectiveness. Prim Care Respir J, 2009,18 : 76-82.
  • 9Everard ML, Devadason SG, Le Souef PN. Flow early in the inspiratory manoeuvre affects the aerosol particle size distribution from a Turbuhaler. Respir Med, 1997, 91: 624- 628.
  • 10缪旭,刘旭,苏健芬,吴传斌.影响干粉吸入剂雾化和沉积性能的制剂因素[J].国际药学研究杂志,2011,38(1):42-46. 被引量:20

二级参考文献61

  • 1田治科,潘一斌,黄雅琴.吸入粉雾剂给药装置的研究进展[J].中国药业,2005,14(1):23-24. 被引量:8
  • 2高静,储藏,丁雪鹰,高申,王秀冬.蛋白质和多肽类药物微粉化技术研究进展[J].世界临床药物,2006,27(10):631-635. 被引量:2
  • 3史宁,吴久鸿.干粉吸入剂的研究进展[J].中国新药杂志,2007,16(12):922-925. 被引量:21
  • 4张志荣,主编.靶向治疗分子基础与靶向药物设计[M].北京:科学出版社,2006.3-20.
  • 5Gryan SA.Carrier-based strategies for targeting protein and peptide drugs to the lungs[J].AAPS J,2005,7(1):E20-E41.
  • 6Zeng XM,Martin AP,Marriott C.et al.The influence of carrier morphology on drug delivery by dry powder inhalers[J].Int J Pharm,2000,200(1):93-106.
  • 7Abbns A,Srour M,Tang P,et al.Sonocrystallisation of sodium chloride particles for inhalation[J].Chem Eng Sci,2007,62(9):2445-2453.
  • 8Herbert C,Li L,Hu TT,et al.Production of salbutamol sulfate for inhalation by high-gravity controlled antisoivent precipitatian[J].int J Pharm,2007,331(1):93-98.
  • 9Okamoto H,Danjo K.Application of supercritical fluid to preparation of powders of high-molecular weight drugs for inhalation[J].Adv Drug Deliv Rev,2008,60(3):433-446.
  • 10Bosquillon C,Rouxhet PC,Ahimou F,et al.Aerosolization properties,surface composition and physical state of spraydried protein powders[JJ.J Control Release,2004,99(3):357-367.

共引文献38

同被引文献23

  • 1金哲,王广发.慢性阻塞性肺疾病全球倡议(2014更新版)解读[J].中国医学前沿杂志(电子版),2014,6(2):94-97. 被引量:140
  • 2刘治军,傅得兴.食物-抗感染药物的相互作用研究进展[J].临床药物治疗杂志,2007,5(3):42-49. 被引量:8
  • 3American College of Clinical Pharmacy.The Definition of Clinical Pharmacy[J].Pharmacotherapy,2008,28(6):816-817.
  • 4YANG C L.The reviewed of chronic disease health management at home and abroad [J]. 齐鲁护理杂志,2009,15(15):40-41.
  • 5LASMAR L, CAMARGOS P, CHAMPS N S, et al. Adherence rate to inhaled corticosteroids and their impact on asthma control [J]. Allergy, 2009,64(5):784-789.
  • 6The Chinese medical association respiratory neurology of asthma group. The bronchial asthma bronchial asthma prevention guide [J]. 中华结核和呼吸杂志,2008,31(3):177-185.
  • 7REZNIK M L,SILVER E J,CAO Y. Evaluation of MDI-spacer utilization and technique in caregivers of urban minority children with persistent asthma [J]. J Asthma, 2014,51(2):149-154.
  • 8CLAUDE L,VIRGINIA S T. National Asthma Education and Prevention Program Expert panel report 3 EPR 3 guidelines for the diagnosis and management of asthma summary report 2007 [J]. J Allergy Clin Immunol, 2007,120(5):94-138.
  • 9LAVORINI F,MAGNAN A,DUBUS J C,et al.Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD [J]. Respir Med,2008,102(4):593-604.
  • 10YUAN H L,YAN X,ZHOU S Q. Education practice of Chronic airway disease patients using inhalant medicine [J].中国医院药学杂志, 2013,33(22):1886-1889.

引证文献2

二级引证文献40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部