摘要 湿通电法是加速聚乙烯醇纤维水泥基复合材料中钢筋锈蚀的一种有效方法。在本试验中将电流设定为一恒定值,测试在不同聚乙烯醇(polyvinyl alcohol简称PVA)纤维掺量下的闭合回路电阻;以及在NaCl溶液侵蚀下PVA纤维水泥基复合材料的钢筋锈蚀率。试验结果表明,恒电流条件下,PVA纤维掺量的增加能提高水泥基复合材料的抗渗性,但对钢筋锈蚀率影响不大。 Wet energized is a method which is used to accelerate the reinforcement corrosion in the Polyvinyl alcohol fiber cementitious composites .In this test , the current is set to be a constant value , Used for testing the closed loop resistance under different PVA ( polyvinyl alcohol ) fiber content , and testing the reinforcement corrosion rate of the Polyvinyl alcohol fiber cementitious composites under the erosion in NaCl solution .The result showed that the increased of PVA fibers content can improve the impermeability of PVA fiber cementitious composites when the current is a constant value , but take little effect on reinforcement's corrosion rate .
出处 《内蒙古工业大学学报(自然科学版)》 2013年第3期225-229,共5页 Journal of Inner Mongolia University of Technology:Natural Science Edition
基金 国家自然科学基金项目(No.50968011 51168033 51368041) 内蒙古自然科学基金项目(No.2012MS0706 2013MS0709) 内蒙古自治区高等学校科学研究项目(No.NJZY12058 NJZY13104)
关键词 湿通电法 PVA纤维 锈蚀率 电阻 抗渗性 Wet energized method Polyvinyl alcohol fiber Corrosion rate Resistance Impermeability
  • 相关文献

参考文献8

二级参考文献19

  • 1赵铁军.高性能混凝土的渗透性研究:博士学位论文[M].北京:清华大学土木系,1997..
  • 2Toshiyuki Kanakubo, Katsuyuki Shimizu, Makoto Katagiri,et al. Tensile characteristics eva luation of DFRCC-round robin test results by JCI-TC-.
  • 3Gregor Fischer, Victor C.Li. Effect of matrix ductility on deformation behavior of steel reinforced ECC flexural members under reversed cyclic loading conditions. ACI Structural Journal, 2002, 99(6):781-790.
  • 4Katsuyuki Shimizu, Toshiyuki Kanakubo, Tetsushi Kanda,et al.Shear behavior of steel reinforced PVA-ECC beams. 13th World Conference on Earthquake Engineering Vancouver, B.C., Canada, 2004, August 1- 6, Paper No.704.
  • 5Lee H S, Noguchi T, Tomosawa F. Evaluation of the bond properties between concrete and reinforcement as a function of the degree of reinforcement corrosion [J]. Cement and Concrete research, 2002 (32) : 1313-1318
  • 6Auyeung Y B, Balaguru P, Chung L Bond behavior of corroded reinforcement bars [J]. ACI Materials Journal, 2000,97 (2): 214
  • 7Li C Q. Initation of chloride-induced reinforcement corrosion in concrete structural members-experimentation [J]. ACI Structural Journal, 2001, 98 (4): 502-510
  • 8GB 50010-2002.混凝土结构设计规范[S],2002.
  • 9吴中伟,韩素芳.预拌混凝土和高性能混凝土技术的现状与发展[J].建筑技术,1997,28(7):463-465. 被引量:21
  • 10陈肇元.高强混凝土与高性能混凝土(续1)[J].建筑技术,1997,28(10):723-725. 被引量:15