摘要
对高压低温液氮泵泵头经常性泄漏的故障原因进行分析,找到了泄漏的主要原因,并提出针对性的处理对策,降低泄漏故障。
This paper studied the failure cause of leakage frequently occurred on HP low temperature liquid nitrogen pump head and presented the treatment measures that dramatically decreased the leakage failUFO.
出处
《大氮肥》
CAS
2013年第5期312-314,共3页
Large Scale Nitrogenous Fertilizer Industry
关键词
液氮泵泵头泄漏原因分析处理对策
liquid nitrogen pump
pump head
leakage
cause analysis
treatment measure