针对煤制烯烃装置压缩机干气密封运行中出现的问题,对造成干气密封失效的原因进行分析,提出干气密封在操作维护中的注意事项和改造建议。
This paper studied the problems occurred in compressor dry gas seal in CTO plant, analyzed the factors causing dry gas seal failure, and presented the precautions and modification suggestions during op eration and maintenance.