某集团公司新建的200kt·a-1铜电解工程电解槽安装采取了分区精确控制,从基础施工、支架梁柱施工、支墩摆放、槽体安装防腐蚀、定位针板安装等自下而上精确控制,加上优质的防腐蚀施工质量对电解槽使用寿命的保证,使得生产中初装槽数量增加,提高了生产效率,确保了生产能长周期稳定高效运行,降低了生产故障及检修成本,为该公司发展提供了有力保障。
Partitioned precise control was conducted during the foundation construction, support beams construction, piers layout, anti-corrosion installation and positioning needle plate installation in the cell installation for a new 200 kt · a^- 1 copper electrolysis engineering. Coupled with excellent anti corrosion construction quality, the service life of electrolyzer can be ensured, which made the number of initial installation cells during production increased, the efficiency improved, ensuring that the production can run stably and efficiently for a long time, the production breakdowns and repair costs can be reduced.