期刊文献+

2D/3D影像配准在鼻咽癌放疗中的应用 被引量:3

Application of 2D/3D Image Registration in the Radiotherapy of Nasopharyngeal Carcinoma
下载PDF
导出
摘要 目的研究2D/3D像配准方法对鼻咽癌放疗中计划靶区PTV外扩距离的影响。方法应用OBI(On Board Image,OBI)系统获取2D影像(kV图像和PV图像)和3D影像(CBCT图像),将获取的2D和3D影像分别经DRR配准系统和模拟定位CT进行图像配准,确定前后、头脚、左右3个方向上的摆位误差,再由2种PTV外扩公式计算3个方向上的PTV外扩距离。结果 2D和3D影像配准的PTV外扩值有所不同。kV,PV,CBCT三者配准误差相互比较P>0.05,无统计学意义。结论 kV图像和PV图像和CBCT图像都能很好地验证照射野位置。CBCT图像可以分析三维方向的影像误差,降低了2D图像影像重叠产生的摆位误差的影响。 Objective To study the effect of 2D/3D image registration on the extended distance of planning target volume (PTV) in the radiotherapy of nasopharyngeal carcinoma (NPC). Methods Using OBI system to obtain two-dimensional images (kV images and PV images) and three-dimensional images (CBCT images). Then registering 2D and 3D images by using DRR registration system and simulation positioning CT respectively to get the set-up errors of VRT, LNG, LAT. Then calculating the values of PTV extended distance of VRT, LNG, LAT with two kinds of PTV expansion formulas. Results The values of PTV extended distance between 2D and 3D images are different while there is no signiifcance in registration errors among kV, PV, CBCT images (P〉0.05). Conclusion Both of 2D images (kV images and PV images) and 3D images (CBCT images) can verify the radiation field well. 3D image errors can be analyzed with CBCT images, which can reduce the inlfuence of set-up errors caused by image overlapping of 2D images.
出处 《中国医疗设备》 2013年第10期115-116,123,共3页 China Medical Devices
关键词 影像配准 鼻咽癌 计划靶区 kV图像 PV图像 CBCT图像 image registration nasopharyngeal carcinoma planning target volume kV images PVimages CBCT images
  • 相关文献

参考文献6

二级参考文献18

  • 1戴建荣,胡逸民.图像引导放疗的实现方式[J].中华放射肿瘤学杂志,2006,15(2):132-135. 被引量:184
  • 2胡逸民 张红志 戴建荣 胡逸民 主编.治疗计划的设计与执行[A].胡逸民,主编.肿瘤放射物理学[C].北京:原子能出版社,1999.463-471.
  • 3Creutzberg CL, Althof VGM, De Hong M, et al. A quality Control Study of the accuracy of patient positioning in irradiation of pelvic fields. Int J Radiat Oncol Phys,1996 ,34 :697-708.
  • 4戴建荣.治疗计划的设计与执行//胡逸民,主编.肿瘤放射物理学.北京:原子能出版社,1999:464.
  • 5Hanley J, Lurrdey MA, Mageras GS, et al. Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate, Int J Radiat Oncol Biol Phys, 1997,37:435-444.
  • 6Hunt MA, Schultheiss TE, Desobry GE, et al. An evalution of setup uncertainties for patients treamed to pelvic sites. Int J Radiat Oncol Biol Phys, 1995,30:227-233.
  • 7Stroom JC, De Boer HC, Huizenga H, et al. Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability. Int J Radiat Oncol Biol Phys, 1999,43:905-919.
  • 8Remeijer P, Geerlof E, Ploeger L, et al. 3-D portal image analysis in clinical practice : an evaluation of 2-D and 3-D analysis techniques as applied to 30 prostate cancer patients. Int J Oncol Biol Phys, 2000,46 : 1281-1290.
  • 9Fu W, Yang Y, Li X, et al. Dosimetric effects of patient rotational setup errors on prostate IMRT treatments. Phys Med Biol,2006,51: 5321-5331.
  • 10Astreinidou E, Bel A, Raaijmakers CP, et al. Adequate margins for random setup uncertainties in head-and-neck IMRT. Int J Radiat Oncol Biol Phys ,2005 ,61:938-944.

共引文献37

同被引文献35

  • 1罗久伟,苏衍峰.颈椎椎间孔大小与脊神经根型颈椎病的关系研究[J].中国医学影像技术,2009,25(S1):204-205. 被引量:13
  • 2张翼,王满宁,宋志坚.脊柱手术导航中分步式2D/3D图像配准方法[J].计算机辅助设计与图形学学报,2007,19(9):1154-1158. 被引量:11
  • 3Kaatee RS,Olofsen MJ,Verstraate MB,et al.Detection of organ movement in cervix cancer patients using a fluoroscopic electronic portal imaging device and radiopaque markers[J].Int J Radiat Oncol Biol Phys,2002,54(2):576-583.
  • 4Yee D,Parliament M,Rathee S,et al.Cone beam CT imaging analysis of interfractional variations in bladder volume and position during radiotherapy for bladder cancer[J].Int J Radiat Oncol Biol Phys,2010,76(4):1045-1053.
  • 5Qiu W,Pengpan T,Smith ND,et al.Evaluating iterative algebraic algorithms in terms of convergence and image quality for cone beam CT[J].Comput Methods Programs Biomed,2013,109(3):313-322.
  • 6Buchali A,Koswig S,Dinges S,et al.Impact of the falling status of the bladder and rectum on their integral dose distribution and the ovement of the uterus in the treatment plnning of gynaecological cancer[J].Radiother Onco1,1999,52(1):29-34.
  • 7Kim TH,Chie EK,Kim DY,et al.Comparison of the belly oard device method and the distended bladder method for reducing iradiated small bowel volumes in preoperative radiotherapy of rectal cancer patients[J].Int J Ra diat Oncol Biol Phys,2005,62:769-775.
  • 8Van de Bunt L,van der Heide UA,Ketelaars M,et al.Conventional, conformal and intensity-modulated radiation therapy treatment planning of external beam radiotherapy for cervical cancer:The impact of tumer regression[J].Int J Radiat Oncol Biol Phys,2006,64(1): 189-196.
  • 9Tyagi N,Lewis JH,Yashar CM,et al.Daily online cone beam computed tomography to assess interfractional motion in patients with intact cervical cancer[J].Int J Radiat Oncol Biol Phys,2011, 80(1):273-280.
  • 10Lubelski D, Derakhshan A, Nowacki AS, et al. Predicting C5 palsy via the use of preoperative anatomic measurements[J]. Spine J, 2014, 14(9): 1895-1901.

引证文献3

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部