对宁德一井数字化气氡观测资料分析研究结果显示,恒流泵和脱气装置的正常与否对于获得真实可靠的观测结果具有重要作用,保障气氡观测仪器的正常是数字化气氡观测的重要环节之一。研究结果表明,宁德一号井数字化气氡变化特征主要受气温、水位的影响,分析和排除这些因素的影响是数字化气氡观测资料分析和应用的基础。
The analysis of Ningde-1 well digital gas radon observation data shows that whether the constant flow pump and degasser are normal or not play an important role in getting real reliable observation re- sults, and to keep the gas radon observation instrument normal is one of the important link of digital gas radon observation. The results show that the Ningde-1 well digital gas radon variation characteristics are mainly affected by temperature, water level. Eliminating these influence factors is necessary for the analy- sis and application of digital gas radon observation.