钢绞线预应力的改变对自复位钢框架性能影响 被引量:4

Influence of prestress change in stand on seismic behavior of self-centering frame
下载PDF
导出
摘要 通过ANSYS模拟和试验结果对比,说明了模拟方法的正确性。在此基础上,通过改变自复位钢框架钢绞线上施加预应力大小,建立了四个单层单跨自复位钢框架结构模型。对比分析了钢框架上角钢Mises应力云图、力-位移滞回曲线、结构骨架曲线以及刚度退化曲线。研究表明,随着钢绞线预应力的增加,钢框架刚度增大,屈服荷载与极限荷载增加,自复位钢框架耗能能力稍微降低,自复位能力明显增强。 The correctness of the modeling method was illustrated by comparing the ANSYS simulation with the test result. Based on the illustration, four single-layer self-centering frames were set up by changing the prestress in stand of the self-centering frame structure. On the basis of the finite element simulation, the Mises stress cloud on angle, force-displacement hysteresis curves, skeleton curves, and the stiffness degradation in the steel frame were analyzed. The research shows that along with the increase of the prestress in strand, the stiffness of self-centering frame increases, the yield load and ultimate load increase, and the capability of self-centering frame increases, but the energy dissipation of the self-centering frame structure slightly decreases.
出处 《苏州科技学院学报(工程技术版)》 CAS 2013年第3期28-31,共4页 Journal of Suzhou University of Science and Technology (Engineering and Technology)
基金 国家自然科学基金项目(51378326) 江苏省结构工程重点实验室开放课题(ZD1204)
关键词 ANSYS模拟 自复位钢框架结构 钢绞线 预应力 角钢 抗震性能 ANSYS simulation self-centering frame structure stand prestress angle seismic behavior
  • 相关文献

参考文献4

  • 1Rojas P,Ricles J M,Sause R.Seismic performance of post-tensioned steel moment resisting frames with friction devices[J].Journal of Structural Engineering,2005,131 (4):529-540.
  • 2Constantin Christopoulos.Self-centering post-tensioned energy dissipating (PTED) steel frames for seismic regions[J].Journal of Structural Engineering,2002,87(4):59-146.
  • 3Hukelbridge A A.Earthquake simulation tests of a nine story steel frame with columns allowed to uplift[R].University of California,Berkely,1977.
  • 4潘振华,潘鹏,邱法维,叶列平,钱稼茹.具有自复位能力的钢结构体系研究[J].土木工程学报,2010,43(S1):403-410. 被引量:17

二级参考文献24

  • 1周云,邓雪松,汤统壁,吴从晓,聂一恒,丁鲲.中国(大陆)耗能减震技术理论研究、应用的回顾与前瞻[J].工程抗震与加固改造,2006,28(6):1-15. 被引量:69
  • 2Christopoulos C,Filiatrault A,Uang C M,et al.Posttensionedenergy dissipating connections for moment-resisting steel frames. Journal of Structural Engineering ASCE . 2002
  • 3Garlock M M,Ricles J M,Richard S M.Experimentalstudies of full-scale posttensioned steel connections. Journal of Structural Engineering ASCE . 2005
  • 4Kim H J,Christopoulos C.Friction damped posttensionedself-centering steel moment-resisting frames. Journal of Structural Engineering ASCE . 2008
  • 5Lin Y C,Ricles J,Sause R,et al.Earthquake simulationson a self-centering steel moment resisting frame with webfriction devices. The 14th World Conference onEarthquake Engineering . 2008
  • 6Rojas P,Ricles J,Sause R.Seismic performance ofposttensioned steel moment resisting frames with frictiondevices. Journal of Structural Engineering ASCE . 2005
  • 7Tremblay R,Lacerte M,Christopoulos C.Seismic response ofmulti-storey buildings with self-centering energy dissipative steelbraces[J ]. Journal of Structural Engineering ASCE . 2008
  • 8Peng S W.Large scale testing of seismically resistantmoment connections for concrete filled tube column-to-WFbeam hybrid systems. . 2001
  • 9Christopoulos C.Frequency response of flag-shaped singledegree-of-freedom hysteretic systems. Journal ofEngineering Mechanics . 2004
  • 10Christopoulos C,Tremblay R,Kim H J,et al.Self-centering energy dissipative SCED bracing system for theseismic resistance of structures:Development andvalidation. Journal of Structural Engineering ASCE . 2008

共引文献16

同被引文献25

引证文献4

二级引证文献10