摘要
采用冷原子吸收法测定出口锌精矿中汞 ,完善了国家标准锌精矿化学分析方法没有汞的测定方法之不足 ,该法测定范围为 0 .0 5~ 0 .3 0 μg/mL ,回收率为 99.6 %~ 10 6 .5 % ,变异系数为 1.81%~ 3 .0 2 % ,能满足微量汞测定要求 .
A new approach is established to determine of mercury in zinc concentrate. It is developed as a GB method for mercury. The method is possible to use with a linear range between 0.05~0.3 μg/mL. The recovery rate and the variety coefficient is in the range of 99.6 %~106.5 %, 1.81 %~3.02 %, respectively. The proposed method has been employed for the determination of trace mercury with a good precision.
出处
《分析测试技术与仪器》
2000年第4期238-241,共4页
Analysis and Testing Technology and Instruments
关键词
冷原子吸收法
锌精矿
汞
测定
cold-vapor atomic absorption
zinc concentrate
mercury