摘要
采用碳酸钡沉淀法去除酸性镀铜液中 SO42 -、Cu2 + 的干扰 ,建立用离子色谱法检测酸性镀铜液中微量氯离子的测定方法 ,在实际检测中表明该方法灵敏度高 。
In this paper, the quantitative method for trace amounts of chloride ion in acidiccopper plating solution by ion chromatography is described. The acidiccopper plating solution contains large amounts of SO 4 2- and Cu 2+ , and trace amounts of chloride ion and so on. To minimize the interfering by sulfate ion and to avoid the damage to anionseparator column by copper ion, a pretreatment using barium carbonate as precipitator is required. Samples were separated completely by this system. The experiment results indicate that the pretreatment method is successful and determination for chloride ion is sensitive and accurate.
出处
《厦门大学学报(自然科学版)》
CAS
CSCD
北大核心
2000年第6期798-802,共5页
Journal of Xiamen University:Natural Science
基金
福建省自然科学基金资助项目!(D990 001)
厦门大学自选课题基金资助项目
关键词
离子色谱法
微量氯离子
酸性镀铜液
测量
acidic-copper plating solution
ion chromatography
trace amounts of chlorided