期刊文献+

启备变冷备用快切装置投入分析 被引量:3

Analysis of Fast Cutting Device Putting into Operation Under Launch Standby Transformer Cold Standby
下载PDF
导出
摘要 通过在神华亿利电厂4×200 MW机组启备变控制系统加装励磁涌流器、整定厂用快切装置运行参数等方法,有效降低了启备变合闸励磁涌流。同时与厂用快切装置配合,在启备变冷备用方式下,电厂厂用电事故时能够可靠切换。并通过启备变冷备方式下切换试验和不同工况下运行管理实践验证,实现了启备变冷备用方式投入,从而减小了变压器的空载损耗,降低了厂用电率,实现了节能的运行方式,经济效益明显。 By means of adding excitation circulation device ior the launch standby transformer control system in the units of 4×200 MW of Shenhua Yili Power Plant and adjusting the operating parameters of fast cutting device, we reduce the excitation circulation under the condition of switching on the launch standby transformer effectively Meanwhile, cooperating with factory fast cutting device, switch reliably in the auxiliary power accident in the way of launch standby transformer cold standby, besides, through switch test in the way of cold standby and management experience verification during different operating condition makes launch standby transformer putting into operation in the way of cold standby come true. Consequently, the loss of no-load for transformer is reduced, the auxiliary power rate is decreased, and energy saving operating method is realized, as a result, the economic benefit is obvious.
作者 刘世雄
出处 《内蒙古电力技术》 2013年第5期52-56,共5页 Inner Mongolia Electric Power
关键词 启备变 冷备用 快切装置 空载损耗 励磁涌流 launch standby transformer cold standbyfast changing.over device loss of no-load excitation surge current
  • 相关文献

参考文献2

  • 1镇江华东电力设备制造厂.励磁涌流抑制原理及涌流抑制器的应用[M].镇江:镇江华东电力设备制造厂,2010.
  • 2镇江华东电力设备制造厂.PZH一1C型微机厂用电快速切换装置说明书[M].镇江:镇江华东电力设备制造厂,2010.