1Calkins H, Kuck K H, Cappato R, et al. 2012 HRS/ EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design[J]. Europace, 2012, 14(4) :528-606.
2Cai L, Yin Y, Ling Z, et al. Predictors of late recurrence of atrial fibrillation after catheter ablation[J]. Int J Cardiol,2013, 164(1) :82-87.
3Cheung J W, Chung J H, Ip J E, et al. Time course of adenosine-induced pulmonary vein reeonnection after isolation: implications for mechanism of dormant conduction [J]. Pacing Clin Electrophysiol, 2012, 35(8) :556-563.
4Cappato R, Negroni S, Pecora D, et al. Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation[J]. Circulation, 2003, 108(13) : 1599-1604.
5Yokoyama K, Nakagawa H, Shah D C, et al. Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus[J]. Circ Arrhythm Electrophysiol, 2008, 1 (5) : 354-362.
6Kuck K H, Reddy V Y, Schmidt B, et al. A novel radiofrequency ablation catheter using contact force sensing: Toccata study [J]. Heart Rhythm, 2012, 9(1) :18-23.
7Reddy V Y, Shah D, Kautzner J, et al. The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study[J]. Heart Rhythm, 2012, 9(11): 1789-1795.
8Haldar S, Jarman J W, Panikker S, et al. Contact force sensing technology identifies sites of inadequate contact and reduces acute pulmonary vein reconnection: a prospective ease control study[J]. Int J Cardiol, 2012: 10-1016. [Epub ahead of print].
同被引文献13
1Nademanee K, McKenzie J, Kosar E, et al. A new approach for catheter ablation of atrial fibrillation: mapping of the electro- physiologic Substra-te[J].J Am Coll Cardiol, 2004, 43 ( 11 ) : 2044-2053.
2Oral H, Chugh A, Good E, et al. Radiofrequency catheter abla- tion o{ chronic atrial fibrillation guided by complex electrograms [J]. Circulation,2007,115(20) :2606-2612.
3Yoshida K,Chugh A, Good E, et al. A critical decrease in dominant frequency and clinical outcome after catheter ablation of persistent at rial fibrillation[J]. Heart Rhythm, 2010,7 (3): 295- 302.
4Haldar S, Wong T. Clinical Impact of a New Open-Irrigated Ra diofrequency Catheter with Direct Force Measurement on Atrial Fibrillation Ablation [J]. International Journal of Cardiology, 2012,168(2) ~ 1160-1166.