摘要 目的探讨关节镜技术和三柱锁定钢板治疗胫骨平台骨折的临床效果。方法采用关节镜技术和三柱锁定钢板固定治疗51例胫骨平台骨折,SchatzkerⅠ~Ⅲ型35例,Ⅳ-Ⅵ型16例;其中,胫骨髁间嵴骨折并前交叉韧带损伤8例,后交叉韧带止点撕脱骨折8例,半月板损伤5例。结果本组随访12~24个月,平均13.6个月。膝关节功能参照Rasmussen评分:优24例,良20例,可6例,差1例,优良率达86.3%。无切口坏死,无固定失败及骨外露发生。有1例伤口感染。结论采用关节镜技术和三柱锁定钢板固定各种胫骨平台骨折是一种可靠方法。 Objective To investigate the efficacy of three columns of locking plate under arthroscopic technique in the treatment of tibial plateau fracture. Methods Using arthroscopic techniques and three column locking plate fixation, 51 patients with tibial plateau fracture underwent surgical procedure from Jan 2007 to Feb 2012 including 35 cases of SchatzkerⅠ -Ⅲ and 16 cases of Ⅳ-Ⅵ. Among them, tibial intercondylar crest fracture with anterior cruciate ligament injury and posterior cruciate ligament insertion avulsion fracture were in 8 cases respectively and meniscus injury in 5 case. Results All patients were followed up for 12-24 months,an average of 13.6 months. Knee function was evaluated by Rasmussen score, excellent in 24 cases, good in 20 cases, moderate in 6 cases, and poor 1 case, excellent and good rates were in 86.3%. No necrosis was found on the skin of incision, one case occurred wound infection No failure of plate fixation and bone exposure occurred in all patients. Conclusion The locking plate and three column fixation under arthroscopy technique is a reliable method in treatment of tibial plateau fracture.
作者 蔡树鹏
出处 《岭南现代临床外科》 2013年第5期403-405,共3页 Lingnan Modern Clinics in Surgery
关键词 胫骨平台骨折 关节镜技术 三柱锁定钢板 Tibial plateau fractures Arthroscopic technique Three column locking plate
  • 相关文献

参考文献7

二级参考文献16

  • 1罗从风,陈云丰,高洪,杨发民,眭述平,曾炳芳.改良双钢板法治疗复杂胫骨平台骨折[J].中华骨科杂志,2004,24(6):326-329. 被引量:299
  • 2校佰平,王晓峰,吴志军,毛为民,周龙,朱文杰.胫骨平台骨折的手术治疗策略[J].中国骨与关节损伤杂志,2005,20(1):29-31. 被引量:59
  • 3Paul JD,Mark RR,Mark RC,et al.Treatment of tibial piateau fractures by limited internal fixation[J].Clin Orthop,1997,(339):47-57.
  • 4Lachiewic ZP,Funcik T.Factions influencing the resnlts of open reduction and internal fixation of tibial plateau fractures[J].Clin Orthop,1990,(259):210.
  • 5贾其余,郑曙翘,董力军,阎红旗,熊进,田小华,方伟.影响胫骨平台骨折手术疗效的相关因素分析[J].中国骨与关节损伤杂志,2007,22(9):726-728. 被引量:39
  • 6Weigel DP, Marsh JL. Highenergy fractures of the tibia plateau. Knee function after longer follow - up. J Bone Joint Surg (Am), 2002, 84 (11): 1541
  • 7Babis GC, Evangelopoulos DS, Kontovazenitis P, et al. High energy tibial plateau fractures treated with hybrid external fixation[J]. J Orthop Surg Res,2011,14(6) :35.
  • 8Pehola EK, Mustonen AO, Lindahl J,et al. Segond fracture com- bined with tibial plateau fracture [J ]. AJR Am J Roentgenol, 2011, 197(6) : 1101-1104.
  • 9Taylor J, Langenbach A, Marcellin-Little DJ. Risk factors for fibular fracture after TPLO [ J ]. Vet Surg, 2011,40 ( 6 ) : 687-693.
  • 10Schatzker J, McBroom R, Bruce D. The tibial fracture. The Toronto experience 1968-1975 [J ]. Clin Orthop Relat Res, 1979, (138) :94- 104.

共引文献431

同被引文献6

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部