期刊文献+

贯入法检测砌筑砂浆抗压强度云南地区测强曲线研究与建立 被引量:1

Study and Establish of Intensity Curve of Yunnan for Testing Compressive Strength of Masonry Mortar by Penetration Resistance Method
下载PDF
导出
摘要 由于贯入法检测砌筑砂浆抗压强度国家统一测强曲线在云南地区的误差较大,因此,根据云南施工地区特点,制作了不同强度等级的砂浆试块,分别测试贯入值和抗压强度,建立了云南地区贯入法测强曲线。验证结果表明,该测强曲线在云南地区是适用的。 Errors of testing compressive strength of masonry mortar in Yunnan by national intensity curve is large, therefore, according to the regional characteristics of Yunnan construction, produced a different intensity level mortar test block, test penetration depth and compressive strength respectively, establish intensity curve of Yunnan for penetration resistance method. The verification results show that, the intensity curve is applicable in Yunnan.
作者 冯维忠 杨昊
出处 《工程质量》 2013年第11期17-19,共3页 Construction Quality
关键词 贯入法 砌筑砂浆 抗压强度 penetration resistance method masonry mortar compressive strength
  • 相关文献

参考文献3

二级参考文献3

  • 1崔士起 孔旭文 郝玉友.贯入法检测砌筑砂浆强度试验研究[A]..第8届全国建设工程无损检测技术学术会议论文集[C].桂林,2004.120-127.
  • 2GJ/T136-2001.贯入法检测砌筑砂浆抗压强度技术规程[S].
  • 3GB/T50315-2000.砌体工程现场检测技术标准[S].[S].,..