摘要
本文通过对罐体设计压力为2.2MPa的液化石油气铁路罐车改装丁二烯时检验中存在问题的分析,提出了对盛装介质低于原设计压力的铁路罐车的检验方法,论述了该方法的合理性,可行性。
By the analysis to existing problems arose in the inspection of railway tanks, in which containing liquid petroleum gas were designed pressure for 2. 2MPa change to fill butadiene, this paper presents inspection methods for the railway tank which containing agent is less than original design pressure, describes its reasonability and feasibility.
出处
《中国锅炉压力容器安全》
2000年第6期43-44,共2页
China Boiler and Pressure Vessel Safety