摘要 介绍了一种适合于便携式二元慢化型高能中子剂量仪的模拟电路系统的设计解决方案。该方案采用低噪声结型场效应管和高性能运算放大器构成具有暗电流消除功能的电荷灵敏前置放大器。前置放大器信号经极零相消后由一级二阶S-K滤波器和低通滤波器成型放大为满足后续电路需求的准高斯信号,然后经过甄别电路和单稳态成型电路把模拟脉冲变成固定宽度的数字脉冲,以便于后续数字电路的进一步处理。由Multisim电路仿真软件仿真结果和实际电路测试结果可知,在计数率从0.1~20 kHz范围内,该方案完全满足便携式二元慢化型高能中子剂量仪的信号处理要求。 It presents a solution of an analog circuit system for a kind of portable Dual -Moderated Dose Detec-tors for High-Energy Neutrons .Using low-noise JFET and high -performance operational amplifier , a kind of charge-sensitive preamplifier with the function of dark current cancellation was set up .Signal from the pre-amplifier was processed by an analog system made up with pole -zero cancellation circuit , second order S -K filter and low-pass filter circuit to form a signal with quasi -Gaussian shape and enough amplitude , which met with the demands of subsequent digitalization circuit .The digitalization circuit was formed by a pulse amplitude discriminator , based on the Schmitt trigger , and a mono -stable trigger and the signal would become a fixed width of digital pulses , which could be read and processed by MCU -cored data acquisition system .Both re-sults from the simulation of EDA software ( Multisim) and the actual circuit test indicated that this design whol-ly met the signal-processing requirements of Dual -Moderated Dose Detectors for High -Energy Neutrons in the count rate range from 0.1~20 kHz.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2013年第9期1057-1061,共5页 Nuclear Electronics & Detection Technology
基金 中央高校基本科研业务费专项资金支持(HEUCF131505)
关键词 高能中子剂量仪 便携 模拟电路 high-energy neutron dosimeter portable analog circuit
  • 相关文献

参考文献6

  • 1李桃生.中子辐射防护监测仪表的发展状况[J].辐射防护通讯,2003,23(2):15-20. 被引量:13
  • 2J. W. Leake. Spherical dose equivalent neutron detec- tor type 0075 A recommendation for change in sensi- tivity [ J 1- Nucl. Instr. oJd Meth. 1980,178 ( 1 ) :287 - 288.
  • 3C. Birattari, A. Ferrari , C. Nuccetelli, et al. An ex- tended range neutron rein counter [ J ]. Nucl. Instr. and Meth. A, 1990,297 ( 1 - 2) :250 - 257.
  • 4H. Toyokawa, A. Uritani, C. Mori, et al. Neutron spectrometer with position - sensitive proportional counters [ J ]. Nuclear Instruments and Methods in Physics Research A, 1996,381 ( 2 - 3 ) :481 - 487.
  • 5乐智希,李桃生,焦南杰,宫存溃.二元慢化型高能中子剂量探测的影响因素研究[J].原子能科学技术,2010,44(B09):467-471. 被引量:3
  • 6Alberto Pullia, Francesca Zocca. Automatic Offset Cancellation and Time - Constant Reduction in Charge- Sensitive Preamplifiers [ J ] . IEEE Transactions On nuclear Science ,2010,57 (2) :732 - 736.

二级参考文献54

  • 1[1]Andersson I O, Braun J. A neutron rem counter. IAEA.Neutron Dosimetry, Proc. Symp. Harwell, Vol. 2,Vienna, 1963:87.
  • 2[2]Bramblett R L, Ewing R k, Bonner T W. A new type of neutron spectrometer. Nucl. Instrum. and Methods,1960,9(1):1.
  • 3[3]Awschalow M. Use of the multispere neutron detector for dosimetry of mixed radiation field. IAEA. Neutron Monitoring, Proc. Symp. Vienna, 1967:289.
  • 4[4]Ing H, Clifford T, Mclean T. ROSPEC-A simple reliable high resolution neutron spectrometer. Radi. Prot. Dose. ,1997, 70(1-4) :273.
  • 5[5]Sannikov A V, Mares V, Schraube H. High energy response function of bonner spectrometers. Radi. Prot.Dose. , 1997,70(1-4):291.
  • 6[6]Boot S J, Gibson J A B. A counter for measuring neutron dose equivalent from thermal to 10 keV. UKAEA, Atomic Energy Research Establishment, Harwell, Report AERER-9357, 1978.
  • 7[7]Hankins D E. A modified A-B rem-meter with improved directional dependence and thermal neutron sensitivity.Health Phys. , 1978,34(2) :249.
  • 8[8]Cosak M, Lesiecki H, Strzelszyk H. Dependence of the response of eight neutron dose equialent survey meters with regard to the energy and direction of incident neutron.Neutron Dosimetry, Proc. Eurtom. 4th Symp.Neuherberg, Report EUP-7448, 1981.
  • 9[9]Leake J W. An improved spherical dose equivalent neutron detector. Nucl. Instrum. and Methods,1968,63:329.
  • 10[10]Portal G, Seguin H, Wagner S. Calibration of dosemeters used for radiation protection in the European community.IAEA. Advances in Radiation Protection Monitoring, Proc.Symp. Stockholm, 1979:639.

共引文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部