期刊文献+

聚合物检测的PEEK超声缓冲杆尾随波消除方法研究

Analysis Method of PEEK Ultrasonic Buffer Rod Trailing Echo Elimination for Polymer Monitoring
下载PDF
导出
摘要 采用波导理论分析了超声波在圆柱杆和水循环套中的传播规律,计算了尾随信号的时间间隔与缓冲杆直径和声速的关系;分析了水循环套的材料、直径、形状对尾随波的影响,并进行了实验验证。实验结果对高温缓冲杆水循环装置的设计提供了理论和实验依据,为聚合物挤出的在线监测奠定了基础。 The wave guide theory was used to analysis the wave theoretical in the cylindrical rod and the water circulating device, calculate the relationship among the intervals of the echoes and the rod's diameter and wave velocity. The impact of water circulating device's material, diameter and shape on trailing echo were analyzed and verified by experiments. The experimental results provided the theoretical and experimental basis for design of high temperature buffer rod water circulation device, laid the foundation for the online monitoring of polymer extrusion.
出处 《塑料工业》 CAS CSCD 北大核心 2013年第11期66-69,共4页 China Plastics Industry
基金 山西省科技攻关项目(20110321029) 国家自然科学基金(61201412) 山西省青年科技研究基金(2012021011-5)
关键词 聚合物 超声检测 缓冲杆 尾随波 Polymer Ultrasonic Testing Buffer Rod Trailing Wave
  • 相关文献

参考文献7

  • 1GALLAGER R G.Low-density parity-check codes[M].Cambridge:MITPress,1963.
  • 2CHUUNG S Y,FOMEY G D,RICHARDSON T J.On the design of low-density parity-check codes within 0.004 5 dB of the Shannon limit[J].IEEE Commun Lett,2001,5(2):58-60.
  • 3JEN C K,CAO B,NGUYEN K T,et al.On-line ultrasonic monitoring of a die-casting process using buffer rods[J].Ultrasonic,1997,35 (6):335-344.
  • 4FRANCA D R,JEN C K,NGUYEN K T,et al.Ultrasonic in-Line monitoring of polymer extrusion[J].Polym Eng Sci,2000,40 (7):82-94.
  • 5SUN Z,JEN C K,SHIH C K.Application of ultra sound in the determination of fundamental extrusion performance:residence time distribution measurement[J].Polym Eng Sci,2003,43 (1):102-111.
  • 6CHEN Y X,WANG Z B,ZHAO X,et al.Ultrasonic monitoring technology for polymer compounding extrusion[J].J Test Eval,2010,38 (1):83-87.
  • 7陈友兴,王召巴,郑建利,金永,喻宾扬.用于聚合物螺杆挤出过程监测的超声缓冲杆[J].高分子材料科学与工程,2010,26(1):158-161. 被引量:7

二级参考文献6

  • 1TABTIANG A, VENABLES R A. Compatibiliser activity and morphology stability during twin-screw extrusion and injection moulding of compatibilised blends [ J ]. Polymer, 2002, 43 ( 17 ) : 4791-4801.
  • 2GONZALEZ-NUNEZ R, ARELLANO M, MOSCOSO F J, et al. Determination of a limiting dispersed phase concentration for coalescence in PA6/HDPE blends under extensional llow [J ]. Polymer, 2001, 42(1 ) : 5485-5489.
  • 3ONO Y, MOISAN J F, JEN C K. Ultrasonic techniques for imaging and measurements in molten aluminum [J ]. IEEE Transactions On Ultrasonics, Ferroelectrics, and Frequen-Toy Control, 2003, 50 (12): 1711-1721.
  • 4SUN Z, JEN C K, SHIH C K. Application of ultrasound in the determination of fundamental extrusion performance: residence time distribution measurement [ J ]. Polym. Eng. Sci., 2003, 43 ( 1 ) : 102-111.
  • 5JENA C evaluation ultrasonic K, LEGOUXA J G, PARENTB L. Experimental of clad metallic buffer rods for high temperature measurements[J]. NDT&E International, 2000, 33 (3): 145-153.
  • 6JENA C evaluation ultrasonic K, LEGOUXA J G, PARENTB L. Experimental of clad metallic buffer rods for high temperature measurements [ J ]. NDT&E International, 2000, 33 (3): 145-153.

共引文献6

相关作者