摘要 评估了浙江省内已经投产的17台SCR烟气脱硝机组的基本情况和投用率,分析了SCR烟气脱硝系统所产生的氨逃逸对空气预热器的影响,同时对几台投运时间较长的SCR烟气脱硝机组的空气预热器阻力进行对比分析,给出了提高燃煤机组SCR烟气脱硝系统投用率的建议,并提出了降低SCR烟气脱硝系统对燃煤机组不利影响的措施。 The background and operation rate of seventeen SCR flue gas denitration units of Zhejiang province are evaluated, and influence pf ammonia slip from SCR system on air preheater is described. Advices of im- proving the operation rate of SCR flue gas denitration units and reducing the adverse effects of SCR system to coal-fired units are given.
出处 《浙江电力》 2013年第11期40-43,共4页 Zhejiang Electric Power
关键词 燃煤发电机组 烟气脱硝 评估 SCR coal-fired power generating units flue gas denitration evaluation SCR
  • 相关文献

参考文献3

二级参考文献7

  • 1SCOT P,SHOZO K,NORIHISA K,et al.Optimizing SCR Catalyst Design and Performance for Coal-Fired Boilers[C].EPA/EPRI 1995 Joint Symposium Stationary Combustion NO Control.1995.
  • 2JAMES E,TONY E,WILLIAM H,et al.The impact of arsenic on coal fired power plants equipped with SCR[C].ICAC 2002 forum,Operating experience for reducing NOx emissions.2002.
  • 3STOBERT P,WANG JIAN-BO,GEORGE W.SCR experience with high Cao coals[C].Chinese environment science committee DeNOx conference.2006.
  • 4Scot P,Chris D.SCR catalyst management:enhancing operational flexibility[C].Power plant air pollutant control mega symposium.2006.
  • 5SCR脱硝技术与脱硝设备的运行及优化[C].广州:中德技术合作高级培训研讨会,2007.
  • 6朱崇兵,金保升,仲兆平,李锋,陈玲霞,翟俊霞.K2O对V2O5-WO3/TiO2催化剂的中毒作用[J].东南大学学报(自然科学版),2008,38(1):101-105. 被引量:32
  • 7云端,邓斯理,宋蔷,姚强.V2O5-WO3/TiO2系SCR催化剂的钾中毒及再生方法[J].环境科学研究,2009,22(6):730-735. 被引量:52