目的:通过分析医用洁净干烤箱工作原理和特点,研究其自动控制系统和气动系统的常见故障及维修方法。方法:以奥星干烤箱作为研究实例,根据医用洁净干烤箱的高温干热灭菌原理,阐述干烤箱的工作步骤和使用中的注意事项;根据使用经验给出常见报警处理、故障排除和维修方法。结果:奥星干烤箱在正确保养和系统维护下,能够长时间正常运行,无意外情况出现。结论:常用灭菌设备医用洁净干烤箱在使用中应按照规程进行保养维护,定期检查,发现故障及时维修,使其保持长期良好的工作状态。
Objective:To analyze the operation principle and property of medical drying sterilizer.The common faults and repair method for automatic controlling and pneumatic system of drying sterilizer are studied.Methods:Taking Austar drying sterilizer as example,based on the dry-heat sterilization principle,the operating process and using notes are described.Based on the operating experience,normal alarm processing,failure recovery and maintenance methods are given.Results:under proper and systemic maintenance,the Austar drying sterilizer can keep normal operating condition for a long time without any accident.Conclusion:as a kind of familiar sterilization equipment,medical drying sterilizer can hold a good operating state for long time with scheduled maintenance,periodic inspection and timely repair.