摘要
针对填土场地上的某变电站地基沉陷事故,从场地条件、设计选型、施工控制等方面分析了事故的原因,介绍了其加固处理方案,并就该工程总结了几点施工经验,供类似工程参考。
According to the foundation settlement accident at some substation on soft soil site, the paper analyzes the reasons for the accident from the site conditions, the design selection, the construction control, introduces its consolidation treatment scheme, and sums up some construction experience for the project, so as to provide some engineering reference.
出处
《山西建筑》
2013年第35期63-64,共2页
Shanxi Architecture
关键词
填土场地
地基沉陷
不均匀沉降
加固处理
soil-filled site, foundation settlement, uneven settlement, consolidation treatment