摘要
传统的声电类比法在单层微穿孔板吸声结构中的计算,得到广泛应用,但由于在双层微穿孔板结构中存在较大误差,于是提出用传递矩阵法对微穿孔板吸声结构进行分析。本文对比分析声电类比法与传递矩阵法在微穿孔板结构模型中的应用,从而有效设计微穿孔板吸声结构参数设计的实验方案。
The traditional Electro-Acoustic method have been used for calculation of monolayer micro-perforated-panel acoustic absorber structure is popular widely, however, because of considerable error in the multilayer micro-perforated-panel acoustic absorber structure, we propose to analyze the micro-perforated-panel acoustic absorber structure in transfer matrix method.In this paper, according to the comparison and analysis of some data getting from experiments which use the Electro-Acoustic method and the transfer matrix method in the structure of monolayer layer micro-perforated-panel acoustic absorber structure.
出处
《电子世界》
2013年第23期177-178,共2页
Electronics World
基金
质检公益性行业科研专项项目(项目编号:201310004)
重点科技攻关项目<新型光通讯核心模块快速故障诊断与质量评价研究>(项目编号:201210101025)
关键词
声电类比法
传递矩阵
微穿孔板结构
Electro-Acousticmethod
transfer matrix method
Micro-perforated panel structure