摘要
对苏制 670t/h锅炉存在的二次汽超温进行热力校核计算 ,提出改造措施。
Based on the overtemperature of second steam regulating heat surface in 670t/h boiler, the author gives out a thermal performance calculation and proposes modification measures.
出处
《电力学报》
2000年第2期122-124,127,共4页
Journal of Electric Power