期刊文献+

射线数字成像(DR)技术在电力工业检测中的应用 被引量:5

Application of X-ray Digital Imaging(DR)Technology in the Electric Power Industry
下载PDF
导出
摘要 由于电磁式电流互感器是全封闭式的结构,在出现故障的情况下,利用常规方法不能对其内部缺陷实现直观地展现。笔者利用X射线数字成像技术对35kV电磁式电流互感器的内部结构进行透照,能够发现其存在的物理缺陷。在解体后,对所判定的缺陷类型进行验证。试验结果表明,相比其他常规检测方法,X射线数字成像技术能够更直观地发现缺陷的位置,并能够在不解体、主绝缘不破坏的情况下,实现对35kV电流互感器内部结构的可视化分析并准确地确定缺陷性质、程度和类型。 Since the electromagnetic current transiormer ts a tutty enc^u~ , --- be visually shown by using conventional method in the case of failure. Using the X-ray digital imaging technology can show the internal structure of the 35 kV electromagnetic current transformer, and also can discover the physical defects of its existence. After the disintegration, we could verify the type of defects. The experimental results have shown that, compared with other conventional methods for detecting the X^ray digital imaging technology can he more intuitive in finding the location of the defect, and can be used to achieve the visualization of the internal structure of 35kV current transformer without disintegrating and destroying the main insulating, and it can accurately determine the defective nature, extent and type.
出处 《无损检测》 2013年第11期76-78,共3页 Nondestructive Testing
关键词 数字成像 电流互感器 可视化 Digital radiography Current transformer Visualization
  • 相关文献

参考文献7

二级参考文献24

  • 1Pardikar R J. Real Time Radioscopy and Digital Image Processing Techniques for on-line Inspection of Welds in boiler Tubes [J]. Journel of Non-Destructive Evaluation, 2000,20 (3) :68-72.
  • 2Bruce Blakeley. Digital Radiography-is it for you? [J]. BINDT Insight ,2004,146(7) :403-407.
  • 3Mohr G A,Beuno C. GE A-Siflat panel detector in industrial digital radiography [J ]. BINDT Insight, 2002, 144(10).
  • 4Ravindran V R. Digital Radiography Using Flat Panel Detector for t e Non-Destructive Evaluation of Space Vehicle Components [J]. Journal of Non-Destructive Testing & Evaluation, 2005 (4).
  • 5Vaidya P R, Narayana Rao A V S S. Performance Evaluation of the Imaging Plates for Industrial Radiography Application[J]. Journal of Non-Destructive Evaluation, 2000,20(3) : 53-56.
  • 6Pardikar R J. Digital Radiography and Computed Radiography for Enhancing the Quality and Productivity of Weldments in Boiler Components[R]. 17th World Conference on Nondestructive Testing, Oct. 2008, Shanghai, China :25-28.
  • 7GB9706.1-2007/IEC60601-1:1988,医用电气设备第1部分:安全通用要求[S].
  • 8YY/T0063-2007/IEC60336:2005,医用电气设备医用诊断X射线管组件焦点特性[S].
  • 9JJG744-2004,医用诊断X射线辐射源[S].
  • 10GBZ187-2007,计算机X射线摄影(CR)质量控制检测规范[s].

共引文献34

同被引文献38

引证文献5

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部