摘要
目的探讨高分辨率CT(HRCT)在颞骨骨折中的诊断价值。方法收集颞骨骨折患者80例,均行HRCT横断扫描,31例同时行冠状扫描。结果纵行骨折57例,横行骨折16例,混合性骨折7例。颞骨骨折同时伴有听小骨脱位8例,面神经管骨折15例,耳蜗半规管损伤5例。结论 HRCT是诊断颞骨骨折的最佳方法 ,能够确定骨折部位,应为颞骨及颅底骨折常规检查方法。
Objective To evaluate the value of HRCT in the diagnosis of temporal bone fracture. Methods Collecting temporal bone fracture patients 80 case, out of which 31 cases for coronal scan at the same time. Results 57 cases of longitudinal fracture, 16 cases of transrerse fractures, 7 cases of mixed fracture, 8 cases of temporal bone fracture with ear bone dislocation, 15 cases of facial nerve canal fracture, 5 cases of cochlear canal oinjury. Conclusion HRCT is the best method for diagnosis of temporal bone fracture, it can determine the fracture site, so it shall be the routine inspection method for the temporal bone and the fracture of the skull base.
出处
《中国实用医药》
2013年第32期12-13,共2页
China Practical Medicine
基金
福建医科大学附属第一医院闽南分院医学科研专项基金(项目编号:MNZX-10-4)