期刊文献+

韶钢120t转炉OG除尘系统中水处理异常状况的分析及解决方法 被引量:1

Analysis and Solution for Abnormal Water Treatment of120 t Converter OG Dedusting System at SGIS
下载PDF
导出
摘要 对韶钢120 t转炉OG除尘系统水处理异常状况进行了分析与现场调查,在除尘方法中调整添加剂使用量以降低水的高钙硬度值,从而降低设备故障率,增加煤气回收量,减少非计划停产,实现环保节能增效减排. Analysis and site investigation were made for the abnormal situation at the water treatment plant for the OG de- dusting system of 120 t converters. The additive amount for dedusting has been adjusted to reduce the high calcium hard- ness value in water, so as to reduce equipment failure rate, increase the recycling of gas, reduce the unplanned production, and achieve the environmental protection and energy saving efficiency and emissions reduction.
出处 《南方金属》 CAS 2013年第6期15-17,共3页 Southern Metals
关键词 OG除尘 水处理 高钙硬度 OG dedusting water treatment high calcium hardness
  • 相关文献

参考文献3

  • 1冶金工业部协调司,中国冶金建设协会.钢铁企业采暖通风设计手册[M].北京.冶金工业出版社.1996.1251-1257.
  • 2钟澍,单杰山,代洪浪.韶钢三炼钢厂120t转炉除尘系统新OG改造.第七届中国钢铁年会论文集:中集[C].2009.
  • 3冯海斌.120t转炉除尘水处理存在问题及对策[J].环境保护与循环经济,2009,29(12):58-60. 被引量:1

二级参考文献5

同被引文献9

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部