摘要
对韶钢1号高炉(420 m3)冷却壁损坏的原因进行分析,针对不同的漏水,采取相应的应对措施,避免或减少了由于漏水造成的炉凉及炉缸冻结或炉墙结厚等事故,达到了安全稳定生产的目的.
The causes and influence of damage of cooling walls in No. 1 BF(420 m3) at SISG were analyzed, and in order to avoid or reduce the water leakage resulted in the cooling of the furnace and the hearth freezing or thickening of furnace wall and other accidents, and achieve stable production, corresponding measures were taken for different water leakage.
出处
《南方金属》
CAS
2013年第6期43-45,48,共4页
Southern Metals
关键词
高炉
冷却壁
原因分析
blast furnace
cooling wall
analysis of causes