摘要 对延庆地震台水温观测资料进行分析,发现水温变化与水位变化密切相关;针对观测中出现的典型干扰提出解决办法:在泄流管最高端加装排气管解决憋气问题;在水温地线接入地网前加装电感,解决气氡观测造成的干扰问题等,并提出其他日常观测需注意的事项。 According to the observation data analysis of Wuliying,changes in water temperature and water level are closely related.In connection with the observation of some typical interference,some solutions are suggested:to install the discharge tube in top end can solve exhaust breath problem; to install inductance between the ground of temperature mearsument and access network can solve interference caused by gas radon observation.Some other proceeding should be noted in daily observation are also put forwade.