期刊文献+

反渗透机组停机时冲洗时间对机组运行参数的影响

The Influence of the Washing Time in the Halt of Reverse Osmosis Unit on the Running Parameters of the Unit
下载PDF
导出
摘要 通过对反渗透机组运行一段时间后运行参数变化的分析,推断出停机时冲洗的时间长短对机组结垢情况和运行参数存在着影响。着重论述了反渗透机组在停机时对残留在机组内的浓水冲洗的重要性,通过冲洗时间调整前后数据比对分析,指出了反渗透机组日常科学运行的方向,对延长机组寿命、降低机组运行成本有很好的参考价值。 Through an analysis on the changes of the running parameters of reverse osmosis unit running after a period of time, we can infer that the length of time in stop washing has influence on the fouling conditions and running parameters of the unit. This paper emphatically discusses the importance of washing the thick water remaining in the unit in the stop of reverse osmosis unit, and through the comparative analysis on the data before and after the adjustment of washing time, points out the direction of scientific daily operation of reverse osmosis unit, which has excellent reference value for extending unit' s service life and reducing unit' s running cost.
作者 温国花
出处 《山西科技》 2013年第6期89-90,105,共3页 Shanxi Science and Technology
关键词 反渗透机组 停机冲洗 冲洗时间 运行参数 reverse osmosis unit stop washing washing time running parameter