摘要 目的:研究ACP-215全自动红细胞处理仪制备红细胞制品的可靠性。方法:将研究对象分成两组,对照组采用手工开放式洗涤法制备,试验组采用ACP-215全自动红细胞处理仪制备。解冻去甘油红细胞和洗涤红细胞按照相关标准,分别对实验组和对照组红细胞回收率、游离血红蛋白、甘油含量、残留白细胞、体外溶血试验和细菌培养进行检测分析。结果:对于解冻去甘油红细胞,实验组在红细胞回收率、残留白细胞、甘油含量、体外溶血和细菌培养均好于对照组;对于洗涤红细胞,实验组在红细胞回收率、残留白细胞量和上清液蛋白含量方面优于对照组结论:用ACP-215全自动红细胞处理仪制备红细胞制品,比手工洗涤法更安全可靠,尤其在解冻去甘油红细胞方面,体现的更明显。该仪器有实际应用价值,值得推广。 Objective : To study the reliability of preparing red cell products by ACP-215 automatic red cell treatment instrument. Methods : The subjects were divided into two groups, the control group using manual open washing preparation, the experiment group adopted the ACP-215 automated red cell treatment instrument preparation. Deglycerin erythrocyte and washed red blood cells in accordance with the relevant standards, recovery rate of Ri3C, hemoglobin, glycerol content, cultivation of residual white blood cells, in vitro hemolysis test and bacteria cultivation were detected and analyzed in the experimental group and the control group. Results : To deglycerin erythrocyte, the experimental group in the recovery rate of 1KBC, WBC, cultivation of residual glycerol content, in vitro hemolysis and bacteria cultivation was better than the control group; for the washed red blood cells, the experinlental group in the recovery rate of tKBC, residual white blood cells and supernatant protein content was better than the control group. Conclusions : Using ACP-215 automatic red blood cell processing apparatus for preparation of a red blood cell products, it was more safe and reliable than the hand washing method, especially in deglycerin erythrocyte, The instrument has the practical application value and was worthy of promotion.
机构地区 聊城市中心血站
出处 《医学检验与临床》 2013年第5期32-33,共2页 Medical Laboratory Science and Clinics
关键词 ACP一215全自动红细胞处理仪 手工洗涤 去甘油红细胞 洗涤红细胞 ACP-215 automatic red cell treatment instrument Hand washing Deglycerolized red cells Washed red blood cells
  • 相关文献

参考文献3

二级参考文献6

  • 1金志坚,王拥军,徐芳,徐利虹,阮争平,胡俊锋.细胞洗涤机去甘油化技术的应用[J].中国输血杂志,2006,19(1):55-56. 被引量:6
  • 2中华人民共和国卫生部.中国输血技术操作规程(血站部分)[M].天津:科学技术出版社,1997,81-83.
  • 3Meryman HT.Cryoprotective agents[J].Cryobiology,1971,8(2):173.
  • 4Valeri CR,Ragno G,Van Houten P,et al.Automationof the glycerolization of red blood cells with the high-separation bowl in the Haemonetics ACP215instrument[J].Transfusion,2005,45(10):1621-1627.
  • 5中华人民共和国卫生部.全血及成分血质量标准(附件1)[S].见:中华人民共和国卫生部.血站基本标准.2000.
  • 6Valeri C R,Ragno G,Pivacek LE,et al.A multicenterstudy of in vitro and in vivo values in human RBCsfrozen with 40-percent(wt/vol)glycerol and storedafter deglycerolization for 15 days at 4 degrees C inAS-3:assessment of RBC processing in the ACP 215[J].Transfusion,2001,41(7):993-999.

共引文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部