目的:研究ACP-215全自动红细胞处理仪制备红细胞制品的可靠性。方法:将研究对象分成两组,对照组采用手工开放式洗涤法制备,试验组采用ACP-215全自动红细胞处理仪制备。解冻去甘油红细胞和洗涤红细胞按照相关标准,分别对实验组和对照组红细胞回收率、游离血红蛋白、甘油含量、残留白细胞、体外溶血试验和细菌培养进行检测分析。结果:对于解冻去甘油红细胞,实验组在红细胞回收率、残留白细胞、甘油含量、体外溶血和细菌培养均好于对照组;对于洗涤红细胞,实验组在红细胞回收率、残留白细胞量和上清液蛋白含量方面优于对照组结论:用ACP-215全自动红细胞处理仪制备红细胞制品,比手工洗涤法更安全可靠,尤其在解冻去甘油红细胞方面,体现的更明显。该仪器有实际应用价值,值得推广。
Objective : To study the reliability of preparing red cell products by ACP-215 automatic red cell treatment instrument. Methods : The subjects were divided into two groups, the control group using manual open washing preparation, the experiment group adopted the ACP-215 automated red cell treatment instrument preparation. Deglycerin erythrocyte and washed red blood cells in accordance with the relevant standards, recovery rate of Ri3C, hemoglobin, glycerol content, cultivation of residual white blood cells, in vitro hemolysis test and bacteria cultivation were detected and analyzed in the experimental group and the control group. Results : To deglycerin erythrocyte, the experimental group in the recovery rate of 1KBC, WBC, cultivation of residual glycerol content, in vitro hemolysis and bacteria cultivation was better than the control group; for the washed red blood cells, the experinlental group in the recovery rate of tKBC, residual white blood cells and supernatant protein content was better than the control group. Conclusions : Using ACP-215 automatic red blood cell processing apparatus for preparation of a red blood cell products, it was more safe and reliable than the hand washing method, especially in deglycerin erythrocyte, The instrument has the practical application value and was worthy of promotion.