介绍了与涂硼正比计数管性能参数相关的因素,从涂硼管自身的结构设计、制作工艺、管外慢化体设计的角度,对提高其性能的技术方法进行了综述分析,推导了硼含量和涂硼层厚度与探测效率间的关系,明确了当前提高涂硼层面积、涂硼工艺、耐高温设计的技术动态。分析表明,涂硼正比计数管应向选择性能更佳的填充气体、更成熟的阳极丝安装工艺和涂硼层制作工艺等方向发展。
The factors related to the performance parameters of a Boron-lined proportional counter are discussed in this paper, the approaches and techniques for improving the performance are summarized and analyzed based on the structure design, the manufacture technique and the moderator of the Boron-lined proportional counter. The effects of an enriched 10B and the Boron-lined floor thickness on the detection efficiency are determined, the technical tendency of adding the surface area, the Boron-lined method and the thermostability is illustrated. The Boron-lined proportional counter will be developed in the way of choosing more suitable filling gas, better-developed anode wire mounting technology and Boron-lined technique in the future.
出处
《科技导报》
CAS
CSCD
北大核心
2013年第33期75-79,共5页
Science & Technology Review
基金
国家国防科技工业局军品配套科研项目(JPPT-115-5-882)
关键词
涂硼正比计数管
硼层
阳极丝
填充气体
耐温技术
Boron-lined proportional counter
Boron floor
anode wire
filling gas
thermostability technique